DIAGOSTIC TEST
11
24
1 2 3
1 2 3
WH3
RD3
YES
YES
NO
NO
Test 4 Heater check Trouble Symptom : Motor malfunction, ventilation error
Trouble Symptom : Heater is not working. Drying failure. The designated
temperature is not reached.
Measurement condition :
Power cord is unplugged.
With WH3, RD3 disconnected
from Controller,
WH3
- RD3
resistance
ranges 26
Ω
~32
Ω
?
WH3
- RD3
resistance
ranges 53
Ω
~59
Ω
?
When check thermostat to
Heater,
it is less than 1
Ω
?
Manually get Thermostat
back (Press button )
1. Clean Condensing unit :
2. Check if Lint filter is
damaged or clogged
Heater On/Off occurs
frequently
• Check and replace
controller.
• Relay RTY2, RTY3
• See page 15, PCB
assembly lay-out.
• Replace Heater
• Check Harness
connection