DIAGOSTIC TEST
11
21
NO
NO
YES
YES
NO
YES
1 2 3
WH3
Test 1 : ELECTRIC SUPPLY & CONTROL CHECK
Trouble Symptom : No power to the dryer or the controller
Measurement condition : Power is on.
[Caution] Electric shock. Please test after grounding check.
Power voltage is within
standard range
(AC 215V~245V)?
• Check after pulling white 3 pin
connector out from controller.
• Check the range of white pin
is within
AC 215~245V?
• Check connection of power
cord and harness assembly.
• Check white 1pin-black 1pin of
connector and secure that
range is between AC
215~245V?
Check the short of harness
assembly(white and white wire)
and the connection(WH3)
• Check the
- Circuit breaker
• Check or replace the
controller
• Check or replace the
power cord
In the case that the dryer is not working, when controller is
powered and display button is properly working, Check
RLY1 in the controller.