MAINTENANCE AND SERVICE
17
ENGLISH
Cleaning the 3M Filter
1
Turn off the power to the unit.
2
Open the front cover and remove the air fil-
ter (see “Cleaning air filter”).
3
Remove the 3M Filter.
4
Use a vacuum cleaner to remove dirt, Do
not wash the 3M Filter with water, be-
cause the filter can be damaged.
• The location of the filters may differ, de-
pending on the model.
• We suggest changing the 3M Filter every
6 Months.
• The feature can be changed according to
type of model.
Cleaning the Air Filter
Clean the Air Filter once every 2 weeks or
more if necessary.
1
Turn off the power and unplug the power cord.
2
Open the front cover.
- Lift up both sides of the cover slightly.
* The feature can be changed according to
type of model
3
Hold the knob of the dual protection filter,
lift it up slightly and remove it from the unit.
* The feature can be changed according to
type of model
4
Clean the filter with a vacuum cleaner or
with warm water.
- If dirt is difficult to remove, wash the fil-
ter in lukewarm water with detergent.
5
Dry the filter in the shade.
3M Filter
Code
RUN lamp
Description of the trouble
E1
flashes once
The fault of indoor temperature sensor
E2
flashes twice
The fault of indoor pipe temperature sensor
E6
flashes 6 times
Malfunction of indoor fan motor
Self-Diagnosis Function
In case of error, the display on the indoor unit shown the folloing error codes: