14
Junction Simple Wired Remote controller
Necessary functions before using
Out door
Room Temp
Total on
Central Run
Defrost
Preheat
PQRCFCS0
Lo
Med
200
100
Setting the Low wind to 210
Setting the Medium wind to 175
FAN
SPEED
1
Press the room temperature button and temperature
incrreasing button
▲
same time for 10 seconds
2
Set the volume of each fan speed(Low, Medium, Hi)
by using the temperature control button. Press the fan
speed button to select the fan speed.
The value of E.S.P can be adjusted from 1 to 255.
3
If you press the On/Off button while setting the ESP
function, it will be canceled. (The picture on the left
side is the example of setting the Hi wind to ESP 10.)
4
Press the Fan Speed button and the temperature
increasing button (
▲
) at the same time for 2 seconds.
Then the ESP setting will be activated after the
temperature display flashes three times.
E.S.P function is setting the volume of each fan speed. It is for the convenience of installation. It is
recommended that you should not use this function while using the remote controller.
EX)
* The E.S.P value is set at the proper value at the factory. So it is highly recommended that you should do not
change the E.S.P value at your discretion.
❈
Note : You can set the ESP only indoor is running.
ESP Function