110
Outdoor Unit
DC charging is not performed at Master Outdoor Unit
after starting relay turn on.
DC charging is not performed at Slave1 Outdoor Unit
after starting relay turn on.
DC charging is not performed at Slave2 Outdoor Unit
after starting relay turn on.
DC charging is not performed at Slave3 Outdoor Unit
after starting relay turn on.
System is turned off by Master Outdoor Unit high
pressure switch.
System is turned off by slave1 Outdoor Unit high pres-
sure switch.
System is turned off by slave2 Outdoor Unit high pres-
sure switch.
System is turned off by slave3 Outdoor Unit high pres-
sure switch.
Master outdoor unit Input voltage is over 514V or below 300V(DT3 Model)
Master outdoor unit Input voltage is over 300V or below 173V(BT3 Model)
Slave1 outdoor unit Input voltage is over 514V or below 300V(DT3 Model)
Slave1 outdoor unit Input voltage is over 300V or below 173V(BT3 Model)
Slave2 outdoor unit Input voltage is over 514V or below 300V(DT3 Model)
Slave2 outdoor unit Input voltage is over 300V or below 173V(BT3 Model)
Slave3 outdoor unit Input voltage is over 514V or below 300V(DT3 Model)
Slave3 outdoor unit Input voltage is over 300V or below 173V(BT3 Model)
The First Start Failure by Master Outdoor Unit Inverter
Compressor Abnormality
The First Start Failure by Slave1 Outdoor Unit Inverter
Compressor Abnormality
The First Start Failure by Slave2 Outdoor Unit Inverter
Compressor Abnormality
The First Start Failure by Slave3 Outdoor Unit Inverter
Compressor Abnormality
System is turned off by Master Outdoor Unit DC Volt-
age Over Charging
System is turned off by Slave1 Outdoor Unit DC Volt-
age Over Charging
System is turned off by Slave2 Outdoor Unit DC Volt-
age Over Charging
System is turned off by Slave3 Outdoor Unit DC Volt-
age Over Charging
Master Outdoor Unit Inverter Compressor Fault OR
Drive Fault
Slave1 Outdoor Unit Inverter Compressor Fault OR
Drive Fault
Slave2 Outdoor Unit Inverter Compressor Fault OR
Drive Fault
Slave3 Outdoor Unit Inverter Compressor Fault OR
Drive Fault
Master Outdoor Unit Inverter
Compressor DC link Low Voltage
Slave1 Outdoor Unit Inverter
Compressor DC link Low Voltage
Slave2 Outdoor Unit Inverter
Compressor DC link Low Voltage
Slave3 Outdoor Unit Inverter
Compressor DC link Low Voltage
Master Outdoor Unit High Pres-
sure Switch
Slave1 Outdoor Unit High Pres-
sure Switch
Slave2 Outdoor Unit High Pres-
sure Switch
Slave3 Outdoor Unit High Pres-
sure Switch
Master Outdoor Unit Input Voltage
High/ Low Voltage
Slave1 Outdoor Unit Input Voltage
High/ Low Voltage
Slave2 Outdoor Unit Input Voltage
High/ Low Voltage
Slave3 Outdoor Unit Input Voltage
High/ Low Voltage
Master Outdoor Unit Inverter
Compressor Start Failure
Slave1 Outdoor Unit Inverter
Compressor Start Failure
Slave2 Outdoor Unit Inverter
Compressor Start Failure
Slave3 Outdoor Unit Inverter
Compressor Start Failure
Master Outdoor Unit Inverter DC
link High Voltage
Slave1 Outdoor Unit Inverter DC
link High Voltage
Slave2 Outdoor Unit Inverter DC
link High Voltage
Slave3 Outdoor Unit Inverter DC
link High Voltage
Master Outdoor Unit Inverter
Compressor Over Current
Slave1 Outdoor Unit Inverter
Compressor Over Current
Slave2 Outdoor Unit Inverter
Compressor Over Current
Slave3 Outdoor Unit Inverter
Compressor Over Current
Display Title Cause of Error
1
2
2 3
3
4
1
2
2 4
3
4
1
2
2 5
3
4
1
2
2 6
3
4
1
2
2 8
3
4
1
2
2 9
3
4
Outdoor unit related error
Test Run
Содержание Multi V ARUB Series
Страница 133: ......