- 8 -
ADJUSTMENT INSTRUCTIONS
1. Application Object
These instructions apply to the RF-043E Chassis.
2. Specification
(1) Because this is not a hot chassis, it is not necessary to
of 25±5°C of temperature and 65±10% of relative humidity
if there is no specific designation otherwise..
(4) The input voltage of the receiver must keep 100~220V,
(5) The receiver must be operated for about 15 minutes prior
O
The unit must be Heat Run with a RGB Full pattern, prior to
O
1) Press the POWER ON KEY on Service R/C.
2) OSD display and screen display 100% full WHITE
[
Set is activated HEAT-RUN without signal generator in
[
Single color pattern(RED/BLUE/GREEN) of HEAT-RUN
mode can be used to check PANEL.
Caution) If you turn on a still screen for more than 20 minutes
(1) Install the LGIDS. (idsinst.exe)
After installation has completed, check if the file shown in
(Fig. 1) has been created.
(2) Right click on 'LGIDS' and select ‘Create Shortcut’
Then move the shortcut icon onto the desktop.
(3) Double-click on the ‘LGIDS’ icon on the desktop to
4. HDCP Download
4-1. Setting Up the LGIDS
(1) Click on ‘setup’ to install in your directory.
(2) After installation has completed, check if the file shown on
(Fig. 2) has been created.
(3) Copy the KEY from source CD into the HDCP directory
which was installed just now.
(DVI_orderNo_2003_data)
(4) After running HDCP(application program) which is inside
the HDCP directory, setup the Communication.
Port : COM1(modification possible)
BaudRate : 115200
(Fig. 1)
(Fig. 3)
Содержание MU-50PM10
Страница 24: ... 24 BLOCK DIAGRAM h t t p w w w w j e l n e t ...
Страница 25: ... 25 NOTES h t t p w w w w j e l n e t ...
Страница 35: ...h t t p w w w w j e l n e t ...
Страница 36: ...h t t p w w w w j e l n e t ...
Страница 37: ...h t t p w w w w j e l n e t ...
Страница 38: ...h t t p w w w w j e l n e t ...
Страница 39: ...h t t p w w w w j e l n e t ...