TEST PROCEDURE
RESULTS
NOTE : If the fuse is blown, check the primary, the secondary, and the monitor
switches, H.V.D. and H.V.C. before replacing the fuse.
If the fuse is blown by improper switch operation replace the defective
switch and the fuse at the same time.
Replace just the fuse if the switches operate normally.
Check for continuity of the switch with a
Multi-meter.
Normal
Abnormal
0°c~Approx 150°C
Approx 150°C
Normal :
❥
Grill heater
Approx. 40.7
Ω
(at 20~30°C)
Normal : more than 0.5M
Ω
FUSE
(Wire leads removed.)
HEATER ELEMENT
(Wire leads removed)
OVEN THERMOSTAT
Measure the resistance.
(Multi-meter scale : Rx1)
Measure the resistance with 500V-100M
Ω
insulation resistance meter.
NOTE : Make sure heater is fully cooled when tested.