Component Test Procedure
21
CAUTIONS
1. DISCONNECT THE POWER SUPPLY CORD FROM THE OUTLET WHENEVER REMOVING THE OUT
CASE FROM THE UNIT. PROCEED WITH THE TEST ONLY AFTER DISCHARGING THE HIGH
VOLTAGE CAPACITOR AND REMOVING THE WIRE LEADS FROM THE PRIMARY WINDING OF THE
HIGH VOLTAGE TRANSFORMER. (SEE PAGE 5)
2. ALL OPERATIONAL CHECKS WITH MICROWAVE ENERGY MUST BE DONE WITH A LOAD (1 LITER OF
WATER IN CONTAINER) IN THE OVEN.
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
TRANSFORMER
(Wire leads removed)
1. Measure the resistance.
(Multi-meter scale: R x 1 and R x 100)
❥
Primary winding
Approx: 2
Ω
❥
Secondary winding
Approx: 90
Ω
❥
Filament winding
Less than: 1
Ω
2. Measure the resistance.
(Multi-meter scale: R x 1000)
❥
Primary winding to ground
Normal:
∞
.
❥
Filament winding to ground
Normal:
∞
.
MAGNETRON
1. Measure the resistance.
(Wire leads removed)
(Multi-meter scale: R x 1)
❥
Between filament terminals
Normal: Less than 1
Ω
2. Measure the resistance.
(Multi-meter scale: R x 1000)
❥
Filament to chassis.
Normal:
∞
.
Filament
Winding
Terminal
Filament
Winding
Terminal