GENERAL DETAILS
• The low voltage transformer supplies the necessary
voltage to the micom controller when power cord is
plugged in.
• When the door is closed, the primary switch is ON, the
secondary switch is ON, and the monitor switch opens
(contact COM and NO).
WHEN SELECTING COOKING
POWER LEVEL AND TIME
• The micom controller memorizes the function you set.
• The time you set appears in the display window.
• Each indicator light turns on to indicate that the stage
has been set.
WHEN TOUCHING THE START PAD
• The coil of the relay is energized by the micom
controller.
• Power input is supplied to the high voltage transformer
through the fuse to the primary switch and relay 2.
• Turntable rotates.
• The fan motor rotates and cools the magnetron by
blowing the air(coming from the intake on the
baseplate).
• The air is also directed into the oven to exhaust the
vapor in the oven through the upper plate.
• Cooking time starts counting down.
• 3.2 volts AC is generated from the filament winding of
the high voltage transformer. This 3.2 volts is applied
to the magnetron to heat the magnetron filament
through two noise-preventing choke coils.
• A high voltage of approximately 2100 volts AC is
generated in the secondary of the high voltage
transformer which is increased by the action of the
high voltage diode and charging of the high voltage
capacitor.
• The negative 4,000 Volts DC is applied to the filament
of the magnetron.
WHEN THE OVEN IS SET AT ANY
LEVEL EXCEPT MAXIMUM
• The micom controller controls the ON-OFF time of
relay 5 by the applied signal to vary the average
output power of microwave oven as POWER LEVEL.
(refer to page 1-1)
• One complete cycle of relay 5 is 22 seconds.
WHEN THE DOOR IS OPENED
DURING COOKING
• Both the primary switch and relay 2 are cut off primary
winding voltage of the high voltage transformer.
• ON-OFF of relay 2 is coupled electrically with opening
and closing of the secondary switch.
• When the door is opened, the secondary switch is
opened and when the door is closed, the secondary
switch is closed.
• The cooking time stops counting down.
• Relay stops functioning.
• As the door is opened, if the contact of primary switch
and secondary switch fail to open, the fuse opens due
to the large current surge caused by the monitor
switch activation, which in turn stops magnetron
oscillation.
WHEN TOUCHING THE START KEY
WITH THE GRILL COOKING
FUNCTION SELECTED
• The contacts of the primary switch and the secondary
switch close the circuit.
• A.C. voltage is applied to the grill heater through oven
thermal cut-out as shown by the solid line.
• Turntable rotates.
• Rotisserie Motor rotates.
• The fan motor rotates.
• The air is also directed into the oven to exhaust the
vapor in the oven through the back plate and upper
plate.
Circuit Description
12
PRIMARY
SWITCH
RELAY 2
H.V.
TRANS-
FORMER
MONITOR
SWITCH
L
N
FUSE
SECONDARY
SWITCH
MICOM CONTROLLER
PRIMARY
SWITCH
MONITOR
SWITCH
L
N
FUSE
H.V.
TRANS-
FORMER
RELAY 2
SECONDARY
SWITCH
MICOM CONTROLLER
L
N
E
N
L
G-Y
GRILL
HEATER
RELAY 3
OVEN THERMAL
CUT-OUT
Содержание MH-794GS
Страница 11: ...SCHEMATIC DIAGRAM 11 ...
Страница 32: ...DOOR PARTS 32 13720D 13806D 13581A 14970A 14026A 13552A 13536A 15006A 13213A 14890A ...
Страница 35: ...LATCH BOARD PARTS 35 43501A 466001 466003 466001 44510A 43500A WSZ085 ...
Страница 37: ...BASE PLATE PARTS 37 56170D 647781 WTT030 63303R 63303L 948502 ...
Страница 38: ...MICOM CONTROLLER SCHEMATIC DIAGRAM 40 ...
Страница 39: ...MICOM CONTROLLER P C B LAOUT 41 ...