COMPONENTS
TEST PROCEDURE
RESULTS
OVEN LAMP SWITCH
(Wire leads removed.)
FAN MOTOR
(Wire leads removed.)
TURNTABLE
MOTOR
(Wire leads removed.)
CIRCULATION MOTOR
(Wire leads removed.)
Measure the resistance.
(Ohm-meter scale: Rx1)
Measure the resistance.
(Ohm-meter scale: Rx1000)
Measure the resistance.
(Ohm-meter scale: Rx1)
Normal: Approx. 51 ohm.
Abnormal: Infinite or Several
ohms.
Normal: Approx. 2800 ohm.
Abnormal: Infinite or Several
ohms.
Normal: Approx. 26 ohm.
Abnormal: Infinite or Several
ohms.
NOTE:
After checking for the continuity of switches, make sure that they are
correctly connected.
Check for continuity of the switch
with an Ohm-meter
Door Door
open close
Fig. 30
Fig. 31
Fig. 32
NC
NO
COM
NC
NO
COM