![LG MH-1355M Скачать руководство пользователя страница 32](http://html.mh-extra.com/html/lg/mh-1355m/mh-1355m_service-manual_215748032.webp)
– 32 –
No input can be programmed.
Some inputs can not be
programmed.
Display shows a number or
figure different from one
touched.
Random programming when
pressing other than touch
pads.
Display fixes some figure and
can not accept any input.
Defective membrane key of
P.C.B.
Loose connection.
Test procedure membrane key
of P.C.B. (See page 41.)
Connect them tightly.
Setting time does not count
down when touch Start.
Defective secondary switch or
out of adjustment
Defective membrane key of
P.C.B.
Test procedure secondary
switch. (See page 25.)
Test procedure membrane key
of P.C.B. (See page 41.)
Loose connection.
Test membrane key of P.C.B.
CONDITION
CAUSE
TEST PROCEDURE OR
CORRECTION