Failure mode: type and condition occurs
Failure mode
Cause
Check
Thermistor short error
In Convection cooking mode, if Thermistor
Thermistor Open error
In Convection cooking, if temperature does
1) Check whether controller connector CN9
2) Check whether Thermistor is Open
3) Check whether convection heater working
* Thermistor check (conducted at room temperature measured)
* Normal: approximately 214 KOhm
* Abnormal: infinity, or short-circuited
F-01
not reached above 100'C in 10 min, then
error is displayed
came out
F-02
short then Error F-02 displayed
Check whether Thermistor is Short