4-4
CIRCUIT DESCRIPTION
GENERAL DETAILS
• The low voltage transformer supplies the necessary
voltage to the micom controller when power cord is
plugged in.
• When the door is closed, the primary switch is ON, the
secondary switch is ON, and the monitor switch opens
(contact COM and NO).
WHEN SELECTING COOKING POWER
LEVEL AND TIME
• The micom controller memorizes the function you set.
• The time you set appears in the display window.
• Each indicator light turns on to indicate that the stage
has been set.
WHEN TOUCHING THE START PAD
• The coil of the relay is energized by the micom
controller.
• Power input is supplied to the high voltage transformer
through the fuse to the primary switch and relay 2.
• Turntable rotates.
• The fan motor rotates and cools the magnetron by
blowing the air (coming from the intake on the
baseplate).
• The air is also directed into the oven to exhaust the
vapor in the oven through the upper plate.
• Cooking time starts counting down.
• 3.2 volts AC is generated from the filament winding of
the high voltage transformer. This 3.2 volts is applied to
the magnetron to heat the magnetron filament through
two noise-preventing choke coils.
• A high voltage of approximately 2100 volts AC is
generated in the secondary of the high voltage
transformer which is increased by the action of the high
voltage diode and charging of the high voltage
capacitor.
• The negative 4,000 Volts DC is applied to the filament
of the magnetron.
WHEN THE OVEN IS SET AT ANY LEVEL
EXCEPT MAXIMUM.
• The micom controller controls the ON-OFF time of
relay 2 by the applied signal to vary the average output
power of microwave oven as POWER LEVEL.
(refer to page 1-1)
• One complete cycle of relay 2 is 22 seconds.
WHEN THE DOOR IS OPENED DURING
COOKING
• Both the primary switch and relay 2 are cut off primary
winding voltage of the high voltage transformer.
• ON-OFF of relay 2 is coupled electrically with opening
and closing of the secondary switch.
• When the door is opened, the secondary switch is
opened and when the door is closed, the secondary
switch is closed.
• The cooking time stops counting down.
• Relay stops functioning.
• As the door is opened, if the contact of primary switch
and relay 2 and/or secondary switch fails to open, the
fuse opens due to the large current surge caused by
the monitor switch activation, which in turn stops
magnetron oscillation.
WHEN TOUCHING THE START KEY
WITH THE CONVECTION/GRILL
COOKING FUNCTION SELECTED
• The contacts of the primary switch and the secondary
switch close the circuit.
• A.C. voltage is applied to the grill heater through grill
thermostat as shown by the solid line.
• Turntable rotates.
• The fan motor rotates.
• The air is also directed into the oven to exhaust the
vapor in the oven through the base plate and upper
plate.
L
FUSE
H.V.
TRANS-
FORMER
RELAY 2
MICOM CONTROLLER
SECONDARY
SWITCH
PRIMARY
SWITCH
N
MONITOR
SWITCH
L
FUSE
H.V.
TRANS-
FORMER
RELAY 2
MICOM CONTROLLER
SECONDARY
SWITCH
PRIMARY
SWITCH
N
MONITOR
SWITCH
CONVECTION
HEATER
RELAY 3
L
N
E
N
L
G-Y
RELAY 5
GRILL
HEATER
RELAY 3
L
N
GRILL
HEATER
L
G -Y
N
E
LGE Internal Use Only
Copyright © 2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Содержание MC3283FMPG
Страница 40: ... 6 2 DOOR PARTS EV 13581A ...
Страница 41: ... 6 3 CONTROL PANEL PARTS EV 23572A 23806C 268712 268711 250204 250203 249401 23550C 24930M SUB MAIN ...
Страница 43: ... 6 5 43500B LATCH BOARD PARTS EV 568771 466003 466003 466001 14510L ...
Страница 45: ... 6 7 BASE PLATE PARTS EV 56170D 64970A ...
Страница 46: ......