14
Installation
3
Ins
talla
tion
PORT A of the LW9228I/9226I series
Description
Color
RS-485 +
Red/White
RS-485 -
Black/White
NC
ALARM IN COM
Red
ALARM IN 1
White
ALARM IN 2
Light Green
ALARM IN 3
Yellow
ALARM IN 4
Pink
PORT A of the LW9228/9226 series
Description
Color
RS-485 +
Green
RS-485 -
Blue
NC
ALARM IN COM
Yellow
ALARM IN 1
Pink
ALARM IN 2
Gray
ALARM IN 3
White
ALARM IN 4
Violet
NOTE
RS-485 data communication is not available.
ALARM output connections
Connect the alarm device to the alarm output data port.
Alarm signal output at an event occurrence. You can set the
Alarm Output to the normal open or normal close mode.
1. Connect the RJ-45 Adapter cable to the PORT B (RJ-45)
cable of the camera.
2. Connect the alarm device to the RJ-45 Adapter cable.
When connecting lines, check and connect the color
lines of the each device correctly. Refer to the below
tables for color line information.
Alarm Out connection
E
D
C
B
A
G
F
H
PORT B
RJ-45 Adapter cable
Alarm device
Alarm device
Alarm device
Alarm device
Alarm device
Alarm device
Alarm device
Alarm device
RJ-45 Adapter cable
Port B
RJ-45 Adapter cable
No
Description
Color
A
ALARM OUT [NO1]
White
B
ALARM OUT [COM1]
Orange
C
ALARM OUT [NC1]
Black
D
NC
Red
E
ALARM OUT [NO2]
Green
F
ALARM OUT [COM2]
Yellow