16
ALARM IN connections
Connect external sensors to the 8-pin haness connec-
tor. Each alarm sensor should be connected with G
(GND). Input specifications are low-active, non-volt-
age contact (ON when active) or open collector (Low
when active).
Cautions
Alarm input connection must be connected to only
one port of two communication ports.
Do not connect one alarm sensor to the several
camera’s alarm input connector.
Data Port
B
Data Port
A
Adapter
Adapter
Alarm
sensors (1-4)
Alarm
sensors (5-8)
•
•
Connection of the data port and adapter
for alarm input
Data Port A
No
Description
Color
1
ALARM IN 1
Brown
2
ALARM IN 2
Blue
3
GND
Yellow
4
TRX D -
Green
5
TRX D +
Red
6
GND
Black
7
ALARM IN 3
Orange
8
ALARM IN 4
White
No
Description
Color
1
ALARM IN 1
Black
2
ALARM IN 2
Brown
3
GND
Red
4
TRX D -
Orange
5
TRX D +
Yellow
6
GND
Green
7
ALARM IN 3
Blue
8
ALARM IN 4
White
Alarm sensor 2
Alarm sensor 1
Alarm sensor 3
Alarm sensor 4
•
Содержание LT703