Installation
6RMI0-04C
63
Inverter Single
Fixing Installation Plate
The wall you select should be strong and solid enough to
prevent vibration
1. Mount the installation plate on the wall with
type "A" screws. If mounting the unit on a concrete wall,
use anchor bolts.
•
Mount the installation plate horizontally by aligning the
centerline using Horizontal meter .
2. Measure the wall and mark the centerline. It is also important to use caution concerning the location of the
installation plate. Routing of the wiring to power outlets is through the walls typically. Drilling the hole through
the wall for piping connections must be done safely.
Installation Plate
Chassis
Hook
Type "A" Screws
Ø70(2 11/16)
133(5 3/16)
95(3 11/16)
Right rear piping
Left rear piping
Installation Plate
Place a level on raised tab
Unit Outline
217(8 1/2)
175(6 29/32)
[Unit : mm(inch)]
442(17 13/32)
442(17 13/32)
Ø70(2.76 )
Ø70(2 11/16)
Type 1
• Applied Model
: LS091HSV2/LS121HSV2/LA090HSV2/LA120HSV2
[Unit : mm(inch)]
Ø65(2 19/32)
Ø65(2 19/32)
69(2 11/16)
56(2 3/16)
Right rear
piping
Left rear
piping
Installation Plate
Measuring Tape
Measuring Tape
Hanger
Place a level on raised tab
Unit Outline
207(8 3/32)
105(4 3/32)
460(18 3/32)
570(22 13/32)
Type 2
• Applied Model
: LS181HSV2/LA180HSV2/LA240HSV2
Содержание LSN090HYV
Страница 1: ...6RMI0 04C 60Hz R410A Inverter Single Wall Mounted North America ...
Страница 26: ...Wiring diagrams 6RMI0 04C 25 Inverter Single Models ASNW093F2B2 LAN090HVP ASNW123F2B2 LAN120HVP ...
Страница 29: ...Wiring diagrams 6RMI0 04C 28 Inverter Single Models ASUW093F2B2 LAU090HVP ASUW123F2B2 LAU120HVP ...