ELECTRICAL DATA
Model Number
Nominal Tons Compressor Qty Compressor (A)
Cool / Heat
Fan Qty
Outdoor Unit
Fan (A)
MCA (A)
MOP (A)
LS243HLV
2
1
14.6/14.6
1
0.25
19
30
LS303HLV
2-1/2
1
14.6/14.6
1
0.25
19
30
LS363HLV
2-3/4
1
14.6/14.6
1
0.25
19
30
Table 3: Single Zone Wall Mounted Extended Piping Electrical Data
Voltage tolerance is ±10%.
Maximum allowable voltage unbalance is 2%.
RLA = Rated Load Amps.
MCA = Minimum Circuit Ampacity.
Maximum Overcurrent Protection (MOP) is calculated as follows:
(Largest motor FLA x 2.25) + (Sum of other motor FLA) rounded down
to the nearest standard fuse size.
Recommended fuse size: 25A.