7. MICOM Function & Circuit
7-1 FUNCTION
7-1-1 FUNCTION
1. When the appliance is plugged in, it is set to Medium. Each time the button is pushed, it cycles
through Medium
Medium/High High Low Medium/Low Medium.
2. When the power is initially applied or restored after a power failure, it is automatically set to
Medium.
Temperature
Control
Low
Medium
Low
Medium
Medium
High
High
TEMP
°
F (
°
C) 46.4 (8)
39.2 (4)
37.4 (3)
34.7 (1.5)
30.2 (-1)
ROOM
REFRIGERATOR
22
Содержание LRTN09314SW
Страница 7: ...3854JL2001D C FAN PART AND 6 2 Circuit Diagram ...
Страница 35: ...7 4 MAIN PWB ASSEMBLY AND PARTS LIST 7 4 1 MAIN PWB ASSEMBLY 34 ...
Страница 37: ...FREEZER COOLING 7 5 PWB DIAGRAM 36 ...
Страница 38: ...37 ...
Страница 43: ...P No 3828JD8331B MAY 2005 Printed in México ...