7-24
(TROUBLE 4) Oven seems to be operating but little heat is produced in oven load.
NOTE : Simple test of power output-conducted by heating one liter water for one min. if available.
Minimum 8.5°C temperature rise is normal condition.
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Output is low
Lower than 90% of
rating voltage.
Normal
Defective
Magnetron.
Replace
Magnetron.
Decrease in power
source voltage
with load.
Suggest customer
contact local
electric power
utility co. or
qualified
electrician.
Check the
power source
voltage.
CONDITION
CHECK
RESULT
CAUSE
REMEDY
4. The display
shows F-4.
Abnormal
Normal
Loose connection.
Connect them
tightly.
Check the
connection between
sensor wire and
control PCB.
Abnormal
Normal
Defective sensor.
Replace sensor.
Check the sensor.
Defective door or
control PCB
assembly.
Replace door or
control PCB
assembly.
Содержание LMVM1945SB
Страница 9: ...5 1 SCHEMATIC DIAGRAM OVERALL CIRCUIT DIAGRAM ...
Страница 10: ...5 2 MATRIX CIRCUIT FOR TOUCH KEY BOARD ...
Страница 37: ...8 2 CONTROLLER PARTS I 23506A 268711 ...
Страница 38: ...8 3 CONTROLLER PARTS II 268712 WTT028 250201 23572A 24810P 24781M ...
Страница 40: ...8 5 LATCH BOARD PARTS 43500A WSZ085 43501A 466001 466003 466001 44510A ...
Страница 43: ...8 8 INSTALLATION PARTS 44360A WSZ133 WWZ068 WSZ204 WSZ203 WSZ136 WSZ098 WWZ068 63300M 65862D 65862B 63861A ...
Страница 44: ...8 17 SCHEMATIC DIAGRAM OF P C B ...
Страница 45: ...8 18 PRINTED CIRCUIT BOARD ...
Страница 46: ...P NO 3828W5S3133 June 2003 Printed in Korea ...