7-22
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Fuse blows.
Continuity.
No continuity.
Continuity.
Shorted contact at
the primary switch.
Replace fuse,
primary, monitor
switches, and
P.C.B Assembly.
No continuity.
Normal.
Defective door or
control PCB.
Replace door or
control PCB.
Fuse blows again
Defective Inverter.
Replace Inverter.
Malfunction of the
monitor switch.
Replace fuse,
primary, monitor
switches, and
P.C.B Assembly.
Check continuity
of monitor
switch (with
door closed).
Check continuity
of primary
switch (with
door opened).
Disconnect one
side of the lead
wires connected
from Inverter.
Replace fuse
2. Fuse does not
blow.
No continuity.
Continuity.
No continuity.
Defective power
supply cord.
Replace power
supply cord.
Defective
thermostat.
Replace
thermostat.
Check continuity
of thermostat.
Check continuity
of power supply
cord.
(TROUBLE 2) Oven does not operate at all, Display window does not display any figures,
and no input is accepted.
Содержание LMVM1945SB
Страница 9: ...5 1 SCHEMATIC DIAGRAM OVERALL CIRCUIT DIAGRAM ...
Страница 10: ...5 2 MATRIX CIRCUIT FOR TOUCH KEY BOARD ...
Страница 37: ...8 2 CONTROLLER PARTS I 23506A 268711 ...
Страница 38: ...8 3 CONTROLLER PARTS II 268712 WTT028 250201 23572A 24810P 24781M ...
Страница 40: ...8 5 LATCH BOARD PARTS 43500A WSZ085 43501A 466001 466003 466001 44510A ...
Страница 43: ...8 8 INSTALLATION PARTS 44360A WSZ133 WWZ068 WSZ204 WSZ203 WSZ136 WSZ098 WWZ068 63300M 65862D 65862B 63861A ...
Страница 44: ...8 17 SCHEMATIC DIAGRAM OF P C B ...
Страница 45: ...8 18 PRINTED CIRCUIT BOARD ...
Страница 46: ...P NO 3828W5S3133 June 2003 Printed in Korea ...