5-9
COMPONENT TEST PROCEDURE
CAUTIONS
1. DISCONNECT THE POWER SUPPLY CORD FROM THE OUTLET WHENEVER REMOVING THE
OUTER CASE FROM THE UNIT. PROCEED WITH THE TEST ONLY AFTER DISCHARGING THE HIGH
VOLTAGE CAPACITOR AND REMOVING THE WIRE LEADS FROM THE PRIMARY WINDING OF THE
HIGH VOLTAGE TRANSFORMER. (SEE PAGE 2-1)
2. ALL OPERATIONAL CHECKS WITH MICROWAVE ENERGY MUST BE DONE WITH A LOAD (1 LITER
OF WATER IN CONTAINER) IN THE OVEN.
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
TRANSFORMER
(Wire leads removed)
MAGNETRON
(Wire leads removed)
1. Measure the resistance.
(Select the ohm scale on the meter)
• Primary winding
• Secondary winding
• Filament winding
2. Measure the resistance.
(Select the ohm scale on the meter)
• Primary winding to ground
• Filament winding to ground
1. Measure the resistance.
(Select the ohm scale on the meter)
• Filament terminal
2. Measure the resistance.
(Select the ohm scale on the meter)
• Filament to chassis
Approx.: 0.6 ~ 0.9 ohm
Approx.: 70 ~ 90 ohm
Less than: 1 ohm
Normal: Infinite
Normal: Infinite
Normal: Less than 1 ohm
Normal: Infinite
PRIMARY
TERMINAL
SECONDARY
FILAMENT
WINDING
Содержание LMH1017CVB
Страница 31: ...DOOR PARTS 6 2 13581A 13552A 13213A 14890A 13720D 13551A For Model LMH1017CVST 14026A 14970A 15006A ...
Страница 32: ...CONTROL PANEL PARTS 6 3 24781M 23506A 23572A 268711 WTP015 23551A For Model LMH1017CVST ...
Страница 34: ...LARCH BOARD PARTS 6 5 WSZ085 43501A 466001 43500A 466003 466001 44510A ...
Страница 36: ...BASE PLATE PARTS 6 7 63302A 56170D 63303A 948502 647781 WTT030 WSZ002 WTT021 ...
Страница 37: ...SENSOR PARTS 6 8 WTP002 56501A WTT021 54974T ...
Страница 38: ......
Страница 39: ......
Страница 40: ......