5-3
A. OUTER CASE REMOVAL
1) Disconnect the power supply cord from the outlet.
2) Remove the screws from the rear of the case.
The outer case must be moved backward to be lifted
off.
B. POWER SUPPLY CORD REMOVAL
1) Remove the outer case.
2) Disconnect two terminals, and remove one screw of
the ground terminal.
C. CONTROLLER ASSEMBLY REMOVAL
1) Open the door.
2) Remove the screws which hold the CONTROLLER
ASS’Y to the cavity and of the ground terminal.
3) Disconnect the leadwires from RELAY and connector
of the P.C.B. SUB ASS’Y.
4) Lift up and pull out CONTROLLER ASS’Y carefully
from the cavity.
CAUTION: DISCHARGE THE HIGH VOLTAGE
CAPACITOR BEFORE SERVICING
(refer to page 2-1)
• Microwave power output measurement is made with the
microwave oven supplied at its rated voltage and
operated at its maximum microwave power setting with
a load of (1000 ± 5)g of potable water.
• The water is contained in a cylindrical borosilicate glass
vessel having a maximum material thickness of 3 mm
and an outside diameter of approximately 190mm.
• The oven and the empty vessel are at ambient
temperature prior to the start of the test.
• The initial temperature (T1) of the water is (10±2)°C. It is
measured immediately before the water is added to the
vessel. After addition of the water to the vessel, the load
is immediately placed on the center of the turntable
which is in the lowest position and the microwave power
switched on.
• The time T for the temperature of the water to rise by a
value
∆
T of (10±2)°K is measured, where T is the time
in seconds and
∆
T is the temperature rise. The initial
and final water temperatures are selected so that the
maximum difference between the final water
temperature and the ambient temperature is 5°K.
• The microwave power output P in watts is calculated
from the following formula:
4187 x (
∆
T) + 0.88 x (T
2
- T
0
) x M
T
• T
2
: Temperature after heating
• T
0
: Temperature of bowl
• M : Weight of bowl
is measured while the microwave generator is operating
at full power. Magnetron filament heat-up time is not
included. (about 3 sec)
• The water is stirred to equalize temperature throughout
the vessel, prior to measuring the final water temperature.
• Stirring devices and measuring instruments are selected
in order to minimize addition or removal of heat.
MEASUREMENT OF MICROWAVE POWER OUTPUT
DISASSEMBLY AND ADJUSTMENT
P =
WATER LOAD
TURNTABLE
Remove the screw
Lift up and Pull out Controller ass’y
Содержание LMH1017CVB
Страница 31: ...DOOR PARTS 6 2 13581A 13552A 13213A 14890A 13720D 13551A For Model LMH1017CVST 14026A 14970A 15006A ...
Страница 32: ...CONTROL PANEL PARTS 6 3 24781M 23506A 23572A 268711 WTP015 23551A For Model LMH1017CVST ...
Страница 34: ...LARCH BOARD PARTS 6 5 WSZ085 43501A 466001 43500A 466003 466001 44510A ...
Страница 36: ...BASE PLATE PARTS 6 7 63302A 56170D 63303A 948502 647781 WTT030 WSZ002 WTT021 ...
Страница 37: ...SENSOR PARTS 6 8 WTP002 56501A WTT021 54974T ...
Страница 38: ......
Страница 39: ......
Страница 40: ......