- 32 -
Connecting
cable
Drain hose
Indoor unit tubing
Flare nut
Pipings
Spanner
Torque wrench
Plastic bands
Insulation material
Press the lower left and right side of the unit
against the Installation Plate until the hooks
engage with their slots (sound click).
6. Indoor unit installation.
• Hook the indoor unit onto the upper position of
the installation plate. (Engage the two hooks of
the rear top of the indoor unit with the upper
edge of the installation plate.)
Ensure the hooks are properly seated on the
installation plate by moving it in left and right.
7. Connecting the pipings to the indoor unit.
• Align the center of the pipings and sufficiently
tighten the flare nut with fingers.
• Finally, tighten the flare nut with torque wrench
until the wrench clicks.
Wrench tightening the flare nut with forque
wrench, ensure the direction for tightening fol-
lows the arrows on the wrench.
8. Wrap the insulation material around the con-
necting portion.
CAUTION: Take care to arrange the pipings,
drain hose and cables as the right
upper picture for inserting it into the
indoor unit and refixing the tubing
holder easily.
Pipe Size
Torque
Liquid Side (1/4")
1.8kg m
Liquid Side (3/8")
4.2kg m
Gas Side (1/2")
5.5kg m
Gas Side (5/8")
6.6kg m
Wrap the insulation material around the connecting
portion.
Содержание LM-2422A2L/A3L
Страница 12: ... 12 900 1 225 370 2 3 LM 4822C3L LM 4822A3L ...
Страница 59: ... 59 2 Outdoor 2 1 MAIN P C B ASM LM 2422C2L LM 2422A2L LM 3625C3L A3L LM 3626A3L LM 4822C3L LM 4822A3L ...
Страница 60: ... 60 3 Display Assembly ...
Страница 61: ... 61 Schematic Diagram 1 Indoor 1 1 LM 2422C2L LM 2422A2L LM 3625C3L A3L LM 3626A3L LM 4822C3L LM 4822A3L ...
Страница 62: ... 62 1 2 LM 3620C2L LM 3622A2L LM 3620A2L ...
Страница 63: ... 63 2 Outdoor 2 1 LM 2422C2L LM 2422A2L ...
Страница 64: ... 64 2 2 LM 3625C3L A3L LM 3626A3L ...
Страница 65: ... 65 2 3 LM 4822C3L LM 4822A3L ...
Страница 81: ...P No 3828A20095K January 2005 Printed in Korea ...