Checking Flow
START
Is Pin 57 of Con6002
on Main Board High?
Check PMIC Circuit
Connect FPCB to Main Board
And Check Pin 19 of
Con6003 on FPCB
Is it High?
Replace FPCB
Check the state of
Contact of Vibrator
Re-contact vibrator
Replace Vibrator
Vibrator will
Work properly
No
No
No
Yes
Yes
Yes
Yes
Connect LCD to FPCB,
And check M+
Is it High?
Replace LCD
No
Yes
SETTING : “Vibrate” at Volume of Sounds menu.