8
-
0 Ω
OFF
Other
Short
Open
Normal
Change the sensor
Replace the refrigerator
Check the Temp and
resistance (Table-3)
Result
SVC Action
8-4 Defrost Sensor Error (
Er
dS)
No
1
2
Checking flow
Check for a loose connection.
Check the Orange to Orange.
Result & SVC Action
Check the Brown to Brown.
※
The sensor is determined by
the temperature.
For example, 23 KΩ
indicates -4°F.
<CON7>
<Temperature table-3>
(1) To (2)
23°F / -5°C
32°F / 0°C
41°F / 5°C
50°F / 10°C
59°F / 15°C
Result
38.5 ~ 36.5 KΩ
30.5 ~ 29.5 KΩ
24.5 ~ 23.5 KΩ
20 ~ 19 KΩ
16 ~15.5 KΩ
-