8
-
No
8-6 Freezer Fan Error (Er FF)
1
2
Checking flow
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
Open the freezer door and Check the
air flow.
※
While an error code is displayed,
the fan is not working.
3
Check the Fan motor.
Rotate fan using your hand.
It feel sticky, change the motor.
(Cause of ice or rust inside of motor)
4
Check the Fan motor voltage.
Result & SVC Action
Below 7 V
0 or 5 V
(2) ~ (3)
(1) ~ (3)
Change the PCB
Change the motor
Point
Result
SVC Action
<CON7>
Status
No windy
Windy
SVC Action
Go to 3
Go to 4
(1)(2) (3)
-
23
-
Содержание LFC25776SB
Страница 14: ... 8 5 CIRCUIT DIAGRAM 14 ...
Страница 16: ... 8 16 7 PCB Picture 7 1 Main PCB P No MFG Picture CON7 CON5 CON201 CON4 CON3 CON2 CON1 EBR74796405 2013 03 ...
Страница 17: ... 8 7 2 Display PCB Sub PCB P No Display PCB Picture CON01 17 EBR42479314 2013 03 ...
Страница 65: ...WATER AND ICEMAKER PARTS CAUTION Use the part number to order part not the position number 619A 627A 600B 600F ...