![LG LFC23760SB Скачать руководство пользователя страница 39](http://html.mh-extra.com/html/lg/lfc23760sb/lfc23760sb_service-manual_1903064039.webp)
- 36 -
2. Door Monitor Circuit (LV)
Refrigerator
Pin Number
Pin Number
Voltage
F Door Close
Con 7 Pin 4
Con 7 Pin 5
5 Volts
F Door Open
Con 7 Pin 4
Con 7 Pin 5
0 Volts
R Door Close
Con 8 Pin 3
Con 8 Pin 4
5 Volts
R Door Open
Con 8 Pin 3
Con 8 Pin 4
0 Volts
8-2-3 Temperature Sensor Circuit (Refer to Figure 2)
Voltage supplied to each sensor will range between 0.5 volts -22°F(-30°C) and 4.5 volts 122°F(50°C) depending upon the
temperature in the compartments. A measurement of 0 volts indicates a short in the sensor circuit. A measurement of 5 volts
indicates an open in the sensor circuit.
R-Door S/W
3
Pin
RT sensor
1
4
Pin
Connector 8
2
PIN
11
10
9
8
7
6
5
4
3
2
1
NC
R-Sensor
F-Sensor
Connector 7
Pipe Heater
F-Door S/W
D-Sensor
Fig. 2
1
CON 4
4
C
GY
R-DOOR S/W
D
BN
2
1 BN
RT-SENSOR
3 GY
CON 8
5
6
GY
PR 4
3
9
8
7
BN
WH
BL
BK
YL
10
RD
12
11
F-FAN
STEPPING
MOTOR
HALL
8
9
10
YL
WH
RD
I/M MOTOR
5
6
7
4 BO
BN
BK
BL
S/W
I/M TEST S/W
ICE MAKER
IC
3 BO
PART
STOP S/W
1 GY
I/M SENSOR
2 GY
ICE MAKER UNIT
CON 9
PWB(PCB) ASSEMBLY, MAIN
SB 2
C-FAN
CON101
5
2
3
6
4
BL
BO
RD
CON 5
BO
RD
WH
PK
BK
PR
SB
BL
1 2
4 5 6 7 8
3
1
SB
9
11
13
10
12
WH
PK
BK
PR
14
CON 6
F-SENSOR
D-SENSOR
R-SENSOR
7 6 5
YL
2
3
10
7
11
6
8
9
BO
BO
WH
WH
BL
BL
1
4
CON 7
A
B
F-DOOR S/W
1
2
3
4
BN
SB
PK
PIPE HEATER
5
PK
YL
9
8
PWB(PCB) ASSEMBLY, DISPLAY
M