4-6
Components
Test procedures
Results
Dual surface unit:
Left Front(LF)
Right Front (RF)
Element
1. Refer to page 3-4 for the servicing procedure
2. Set the Multiple meter scale to the R x1
3. Disconnect wires from cook-top elements
4. Touch the ohmmeter test leads to the (4 & 2A)
and (3 & 2A) the meter should indicate :
1) LF element
- (4&2A) -> 41Ω ± 10%
- (3&2A) -> 32Ω ± 10%
2) RF element
- (4&2A) -> 34Ω ± 10%
- (3&2A) -> 58Ω ± 10%
Normal: Approximately
LF element: 38 Ω
RF element: 32 Ω
Normal: Approximately
LF element: 30 Ω
RF element: 54 Ω
3
4
2A
5. Touch the ohmmeter test leads to limiter terminals
1B and 2B.
With the temperature below 150˚F, the meter
should indicate an open circuit(infinite).
With the temperature above 150˚F, the meter
should indicate continuity (0 Ω).
Below 150˚F
open circuit(infinite).
Above 150˚F
continuity (0 Ω)
1B
2B