4-1
COMPONENT TEST
Before testing any of components, perform the following checks:
NOTE:
1. The most common cause for control failure is corrosion on connectors.
Therefore, disconnecting and reconnecting wires will be necessary throughout test procedures.
2. ALL units in the first few days of use should be checked for mis-wiring or loose connections.
1. All/tests/checks should be made with a VOM or DVM having a sensitivity of 20,000 ohms per-volt DC, or
greater.
2. Check all connections before replacing components, looking for broken or loose wires, failed terminals, or
wires not pressed into connectors far enough.
3. Resistance checks must be made with the power cord unplugged from the outlet, and with the wiring
harness or connectors disconnected.
WARNING
• Disconnect power supply cord from the outlet before servicing
• Replace all panels and parts before operating
• Reconnect all grounding devices after servicing
- Failure to do so can result in death or electric shock
NOTE: Below Ω value were tested at room temperature (77F/25°C)
Components
Test procedures
Results
Convection Motor
1. Refer to page 3-10 for the servicing procedure
2. Measure the resistance
(Multiple meter scale: R x 1)
Normal: Approximately
Low-COM : 30 Ω
High-COM : 23.7 Ω
If not replace
Abnormal: Infinite (open)
below 5Ω (shorted)
Содержание LDE4413BD
Страница 49: ...5 3 COMPOSITION OF CONTROL Touch PCB P N EBREBR79627601 P N EBR78789101 P N EBR76332902 NFC and Buzzer PCB ...
Страница 77: ...8 3 LOWER BAKE CONV BAKE CONV ROAST LOWER BROIL ...
Страница 78: ...8 4 UPPER SELFCLEAN LOWER SELFCLEAN ...
Страница 79: ...8 5 OVEN LAMP CLOCK DISPLAY ON ...
Страница 80: ...8 6 CR Cooktop element LR RR Cooktop element ...
Страница 81: ...8 7 LF Cooktop element RF Cooktop element ...
Страница 87: ... EV COOKTOP PARTS 3056 3402 3099 3059 330S 330S 3022 330M 330H 3006 3006 3204 3016 301C ...
Страница 90: ......