16
To set Alarm Input
You can set alarm input mode, alarm index, and
duration time. Preset numbers 1 to 8 are linked to
alarm inputs 1 to 8 respectively. If alarm input 1
comes in, the camera turns to preset position 1, and
to other positions according to alarm input 2 to 8.
1. Press the Set Up button then select the [PRESET]
icon.
2. Press SEL.
The sub menu will appear for [PRESET] setting.
3. Select [Set Alarm Input] option then press SEL.
The sub menu will appear.
4. Use 4 (ON) or 6 (OFF) buttons to select Alarm
Input Mode then press SEL.
ON: Alarm input signals are supplied from external
devices through the ALARM IN connector on the
camera to turn the camera to a preset position.
OFF: The camera ignores alarm inputs.
5. Enter a [Alarm Index] number (1-8).
Note:
The available alarm index differ depending
on cameras. So please refer to camera’s manual.
6. Enter a [Duration Time] (0-255) then press SEL.
Displays the picture at the preset position for the
selected duration. (0; the camera hold at the pre-
set position continuously.)
Alarm input setting is finished and the setting is
memorized to the camera’s memory.
7. Repeat steps 4-6 to set additional Alarm Input.
To set Alarm Output
You can set alarm output mode, alarm index, and
duration time. When alarm inputs are supplied via the
alarm input connector on the camera, the camera
sends output signals via the alarm output connector
on the camera.
Alarm output numbers 1 to 4 are linked to alarm
inputs 1 to 4 respectively. If alarm input 1 comes in,
the camera sends output signals via the alarm
output 1 connector on the camera
Note:
You cannot use this function with a camera
without alarm output connector.
1. Press the Set Up button then select the [PRESET]
icon.
2. Press SEL.
The sub menu will appear for [PRESET] setting.
3. Select [Set Alarm Output] option then press SEL.
The sub menu will appear.
4. Use 4 (ON) or 6 (OFF) buttons to select Alarm
Input Mode then press SEL.
ON: If alarm input comes in, the camera sends
output signals.
OFF: The camera does not send an output signal.
5. Enter a [Alarm Index] number (1-4).
6. Enter a [Duration Time] (1-255) then press SEL.
Sends the output signals for the selected duration.
(0; the camera sends output signals continuously.)
Alarm output setting is finished and the setting is
memorized to the camera’s memory.
PRESET
000
PTZ
PRESET
000
PTZ
[
vV
:
bB
]
Clear All Preset
Clear Group
Set Alarm Input
Alarm Input
: OFF
Alarm Index
: - - -
Duration Time : - - -
<4:OFF , 6:ON> [Num]
PTZ
000
PTZ
000
[
vV
:
bB
]
Set Alarm Ouput
Alarm Output
: ON
Alarm Index
: - - -
Duration Time : - - -
<4:OFF , 6:ON> [Num]
PTZ
000
PTZ
000
LCC-K1000_AABBLLG_ENG 8/9/05 2:55 PM Page 16