Four-Way caSSette | 9
Product Data
Due to our policy of continuous product innovation, some specifications may change without notification.
©
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
general Data / SPeCiFiCationS
Type
Single Zone Four-Way Ceiling Cassette
System (Model) (Indoor Unit / Outdoor Unit)
LC187HV
(LCN187HV /
LUU187HV)
LC247HV
(LCN247HV /
LUU247HV)
LC367HV
(LCN367HV /
LUU367HV)
LC427HV
(LCN427HV /
LUU427HV)
Ceiling Grille Model Number (Sold Separately)
PT-UMC1
PT-UMC1
PT-UMC1
PT-UMC1
Nominal Cooling Capacity (Btu/h)
18,000
24,000
36,000
42,000
Cooling Power Input
1
(kW)
1.26
1.91
2.97
4.07
Nominal Heating Capacity (Btu/h)
20,000
27,000
40,000
47,000
Heating Power Input
1
(kW)
1.50
2.60
3.20
4.05
Power Supply V, Ø, Hz
2
208-230 / 1 / 60
Outdoor Unit Operating Range
Cooling (°F DB)
5-118
Heating (°F WB)
0-64
Indoor Unit Operating Range
Cooling (°F WB)
57-77
Heating (°F DB)
59-81
Indoor Temperature Setting Range
Cooling (°F DB)
65-86
Heating (°F WB)
61-86
Unit Data
Refrigerant Type
3
R410A
Refrigerant Control
EEV
Indoor Unit Sound Pressure Level ±3 dB(A) (H/M/L)
4
38 / 36 / 34
46 / 44 / 43
Outdoor Unit Sound Pressure Level ±3 dB(A) (Cool/Heat)
4
48 / 52
52 / 54
Indoor Unit Net / Shipping Weight (lbs.)
46 / 55
55 / 65
Outdoor Unit Net / Shipping Weight (lbs.)
133 / 148
203 / 227
Grille Net / Shipping Weight (lbs.)
11 / 20
Power Wiring / Communications Cable (No. x AWG)
2
4 x 18
Power Supply (No. AWG)
3 x 12
Compressor (Type x Qty.)
Twin Rotary x 1
Dehumidification Rate (pts./hr.)
5.1
7.7
Fan
Indoor Unit Type x Qty.
Turbo x 1
Outdoor Unit Type x Qty.
Propeller x 1
Propeller x 2
Motor / Drive
Brushless Digitally Controller / Direct
Airflow Rate
Indoor Unit (Max. / H / M / L [CFM])
565 / 494 / 424
600 / 530 / 459
1,060 / 989 / 918
1,060 / 989 / 918
Outdoor Unit (CFM)
2,048
2,048
1,942 x 2
1,942 x 2
Piping
Liquid (in.)
3/8
Vapor (in.)
5/8
Indoor Unit Condensate Drain O.D. / I.D. (in.)
1-1/4 / 1
Additional Refrigerant Charge (oz./ft.)
0.43
Maximum Pipe Length (ft.)
164
246
Piping Length (no additional refrigerant, ft.)
25
Maximum Elevation Difference (ft.)
98
Table 2: Four-Way Ceiling Cassette System General Data.
EEV: Electronic Expansion Valve
IDU: Indoor Unit
ODU: outdoor Unit
Power wiring is field supplied and must comply with the applicable local and national codes.
This unit comes with a dry helium charge.
This data is rated 0 ft above sea level, with 24.6 ft of refrigerant line per indoor unit and a 0 ft level
difference between outdoor and indoor units.
Cooling capacity rating obtained with air entering the indoor coil at 80ºF dry bulb (DB) and 67ºF wet bulb
(WB); and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 60ºF wet
bulb (WB); and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).
1
Power Input is rated at high speed.
2
All power/communication cables to be minimum 18 AWG, 4-conductor, stranded, shielded and must
comply with applicable and national code.
3
Take appropriate actions at the end of HVAC equipment life to recover, recycle, reclaim or destroy R410A
refrigerant according to applicable regulations (40 CFR Part 82, Subpart F) under section 608 of CAA.
4
Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745 and are the
same in both cooling and heating mode. These values can increase due to ambient conditions during
operation.