Explanation 

 module designed to communicate with LG compressor unit, ARUN

 

model series, power code set to 

56kW, software version 4.3, user software 3, 

assigned station / address number “

1

“ 

for communication with 

ARUM--- outdoor unit.  

 
 
Notice: 

If no address has been assigned to the module, the symbol “

- - 

“ will be displayed in the appropriate position 

for the address in the introductory sequence 

 i.e. the system did not auto-address successfully, the outdoor 

compressor unit does not communicate with the KM113.22MV2 module. 
If  several  communication  modules  are  connected  to  one  outdoor  compressor  unit,  each  module  must  have 
different address. 

Upon delivery, the module is delivered with the preset address “1”. 

 

 
 

After these initial sequences, the display will show current status of the operation

 

request

 

Example  

“cO  …  

-

1 …  6““

 

 

Explanation: cooling operating mode, no operation allowed, no power demand, current temperature of the input 
refrigerant piping to the heat exchanger in HVAC -1 

°

C (blue sensor), on the 6 

°

C (red sensor). 

Refrigerant temperature display range MIN = -9, MAX= 99. 
 
 

Attention: 
If the power code is set incorrectly, the safety function of the external compressor unit may be activated. 
When setting the power code, both the module and the device must be  without voltage (changing the power 
code is accepted by the module when the power supply is activated).

 

 

Notice: 
If  several  communication modules  are  connected to  one  outdoor  compressor unit,  each  module  must have  a 
different  address.  The  address  of  the  communication  module(s)  for  internal  communication  between  the 
outdoor  unit  and  the  modules  is  assigned  automatically  during  the  auto-addressing  process  (the  process  is 
activated from the outdoor unit).

 

 
 
 
ADDRESS OF COMMUNICATION MODULE FOR COMMUNICATION WITH COMPRESSOR UNIT: 
 

The  address  of  the  communication  module(s)  for  internal  communication  between  the  outdoor  unit  and  the 
modules  is  assigned  automatically  during  the  auto-addressing  process.  The  process  is  activated  from  the 
outdoor unit (see the relevant manual for the outdoor compressor unit). 
Display of the assigned address - see section "Introductory information sequence". 
 
 

COMMUNICATION MODULE ADDRESS FOR CENTRAL CONTROL IN THE LG SYSTEM:

 

 

The  address  of  the  communication  module(s)  for  central  control  via  the  LG  protocol  (central 
controller/converter) is identical to the MODBUS address. 
 
 
 

 

6.2 INTRODUCTORY INFORMATION SEQUENCE

 

 

Communication module functionality test

 

 

Activate the supply voltage - the display will show the introductory sequence:

 

 
1

ST

 cycle

 

 basic information about hardware, settings and software - example: 

LG 

 Ar 

 56 

 So 

 4.3 

… S

… 3“

 

 
2

nd

 cycle 

 basic information about hardware, settings, software and assigned address - example:

 

LG 

 Ar 

 56 

 So 

4.3 

 So 

… 3 … 1“

 

Meaning - module designed for communication with the LG compressor unit, ARUM / N model series, set power 
56kW, software version 4.3, user software 3, assigned station number/address "1" (set on delivery).

 

 

After these initial sequences, the display will show the current status of the operation request - example:

 

cO  

  -1 

  

6““

 

 

Содержание KM113.22MV2

Страница 1: ...ons Installation Operation 2xRS485 KM113 22MV2 A SET FOR THE APPLICATION OF AN OUTDOOR COMPRESSOR CONDENSATION UNIT FOR A NON ORIGINAL EVAPORATION HVAC UNIT DESIGNED FOR OUTDOOR UNITS LG Electronics model series ARUM ARUN ARUB ARWN ARWB Version 2020 07 23 ...

Страница 2: ...temperature sensors 8 4 5 Connection to an outdoor compressor unit 9 4 6 MOV MV power limitation module connection accessories 9 5 CONNECTION TO SUPERIOR I C HVAC SYSTEM 10 5 1 Control descriptions priorities 10 5 2 Inputs for external control digital analogue 10 Control diagram Power request for analogue input fig 4 11 Logic input control diagram fig 5 11 5 3 Outputs information about the operati...

Страница 3: ... Power supply 230 V AC 10 50 Hz e g from the connected outdoor unit Overvoltage category II Recommended cable CYKY J 3x1 5 Power input Max 30 W Power supply of separate module KM113 22 24 V DC 10 max 800 mA The source must be separated by double insulation SELV Other connected devices Must be separated by double insulation SELV Communication properties with an outdoor unit Two wires at RS485 safe ...

Страница 4: ...EX5 U21 EX6 M21 In applications where the compressor unit is used as a heat source or as a source for several air handling units exchangers it is necessary to use expansion valves with bidirectional flow i e EX4 U31 EX5 U31 EX6 M31 The KM113 27UU module has 1 analogy input 4 digital inputs 2 digital outputs and 2 communication ports RS485 for controlling the compressor unit The MODBUS input output...

Страница 5: ...correct amount of refrigerant in the system with regard to the length of the piping and the size of the heat exchanger in the HVAC 5 Air temperature in front of the heat exchanger Permitted operating air temperature ranges see the documentation of the respective compressor unit usually 18 to 35 C in cooling mode and 10 to 24 C in heat pump mode 6 Function of the I C system the request for cooling ...

Страница 6: ...tion MODBUS I C I C system for HVAC Air inlet HVAC unit Air outlet Temperature sensors on refrigerant piping R410A R32 refrigerant piping Outdoor unit ARUM Module MOV MV Power supply KM113 22MV2 Communication KM113 22MV2 ARUM EEV EX Communication I O I C Communication MOV MV KM113 22MV2 ARUM APPLICATION OVERVIEW DIAGRAM KM113 22MV2 ARUM HVAC I C Supply Temp sensor IN Temp sensor OUT POWER control ...

Страница 7: ...erminals of the communication module and the power supply source Have cable glands suitable for your intended application ready Attach the communication box to a suitable vertical plane use the holes and covers at the rear of the box 4 2 CONNECTION TERMINALS OVERVIEW Connect a suitable power cable e g CYKY J 3x1 5 to the power supply terminals of the communication box auxiliary terminals 1 2 3 ter...

Страница 8: ... in the HVAC system The blue sensor is designed for input of the refrigerant into the heat exchanger that is the small diameter pipes and the red sensor is designed for output of the refrigerant from the heat exchanger large diameter pipes To properly attach sensors to Cu pipes use for example fastening clamps to ensure proper heat transfer to the sensor see Fig After the sensors are attached make...

Страница 9: ...e given unit and the supply terminals in the communication box terminal block no 1 L 2 N PE Connect suitable shielded communication cable between the outdoor compressor unit terminals IDU and OUT COMM box terminals terminal block X1 no 3 A 4 B Attention the polarity must be followed marked A B 4 6 MOV MV POWER LIMITATION MODULE CONNECTION ACCESSORIES Make sure that the compressor unit is without v...

Страница 10: ...tly at the terminals of the communication module KM113 22 MODBUS PROTOCOL CONTROL MONITORING see separate section for description 5 2 INPUTS FOR EXTERNAL CONTROL digital analogue OPERATION ACTIVATION ON OFF Input terminals ON Logic input voltage free contact When the contact 0V D4 is closed terminals 18 22 the operation of the device is allowed when it is opened the operation is stopped The curren...

Страница 11: ...e of the display module using 8 codes C0 C7 or rather H0 H7 The power request algorithm requires at least C1 H1 code i e at least 1 5V to activate the compressor unit The power request algorithm requires at least C0 H0 code that means maximum 1 3V to stop the compressor unit Fig 5 Logic input control diagram free contact type 2 Input terminals POWER 1ST 2ST 3ST logic inputs voltage free contacts n...

Страница 12: ... also shown on the module display using the variable communicated by the MODBUS Defects identified by the communication module Er 2 thermometer error blue Er 6 thermometer error red Er 99 Modbus communication error Er 5 Communication error with the outdoor unit Er XX outdoor unit errors List of error codes of the outdoor unit see the servicing manual of the applied LG equipment If more than one er...

Страница 13: ...DING REGISTRIES Name Address decadically Properties description VERSION 4096 Software version ERROR 4097 Errors according to the device s self diagnostics see the service manual of the LG device error 99 Modbus communication error TEMP1 4098 Refrigerant input temperature to the exchanger 15 C blue sensor smaller diameter TEMP2 4099 Refrigerant output temperature to the exchanger 15 C red sensor bi...

Страница 14: ...epeated the situation will be considered as a MODBUS communication error error Er 99 Notice If an error is active ER the registers are automatically set to 0 Reading the values of the read registers is possible at any time without time limit and does not affect the control by HW signals 6 CONFIGURATION AND CONNECTION CHECK 6 1 SETTING THE POWER CODE AND MODBUS COMMUNICATION ADDRESS Power code and ...

Страница 15: ...button for 5 s to return to point 2 If you do not press the SETTINGS button for 10 seconds the last set value is automatically saved the setting mode is exited and the initial information sequence appears on the display Attention After changing the settings it is necessary to restart the outdoor unit restore power If the outdoor compressor unit is not restarted the changes are not accepted by the ...

Страница 16: ...cted to one outdoor compressor unit each module must have a different address The address of the communication module s for internal communication between the outdoor unit and the modules is assigned automatically during the auto addressing process the process is activated from the outdoor unit ADDRESS OF COMMUNICATION MODULE FOR COMMUNICATION WITH COMPRESSOR UNIT The address of the communication ...

Страница 17: ...sor unit is not enabled contact ON is open the device will not be activated If the operation of the compressor unit is blocked but at the same time the power demand is active this state can be recognized by the case of the operation request letter on the display e g C4 cooling request operation enabled c4 cooling request operation not allowed 3 The analog input test is performed by applying a DC v...

Страница 18: ... and visually check its tightness 6 3 INSPECTION OF SETTINGS DURING OPERATION During operation without deactivating the supply voltage the pressure status of the system if a pressure sensor is installed the set power code the address for central control MODBUS and the last 10 error states of the device can be verified 1 After a short press of the SETTINGS button the display shows the pressure in b...

Страница 19: ...mber Date of sale Seller Installation date Installation performed by The manufacturer provides a 24 month warranty covering the quality of the product starting on the day of sale The warranty covers defects of the purchased product which appear during the warranty period In order to keep your warranty valid the installation must be performed by an authorized person and the Warranty form must be pr...

Отзывы: