background image

InstructIons for:

Belt Driven COMPreSSOrS

model no's: 

SA2010/3, SA2015/3,   

   

SA2020/3, SA2050/3

thank  you  for  purchasing  a  sealey  product.  manufactured  to  a  high  standard  this  product  will,  if  used  according  to  these  instructions 

and properly maintained, give you years of trouble free performance.

sA2050/3, sA2010/3, sA2015/3 & sA2020/3 - 

5  - 06/10/10

1.  SAFetY inStrUCtiOnS

IMPORTANT:

 

PleASe  reAD  tHeSe  inStrUCtiOnS  CAreFUllY.  nOte  tHe  SAFe  OPerAtiOnAl  reQUireMentS,  WArninGS  AnD 

CAUtiOnS. USe tHe PrODUCt COrreCtlY AnD WitH CAre FOr tHe PUrPOSe FOr WHiCH it iS intenDeD. FAilUre tO DO SO MAY 

CAUSe DAMAGe Or PerSOnAl inJUrY AnD Will invAliDAte tHe WArrAntY. PleASe KeeP inStrUCtiOnS SAFe FOr FUtUre USe.

1.2.   GenerAl SAFetY inStrUCtiOnS

familiarise yourself with the application and limitations of the compressor.     

ensure the compressor is in good order and condition before use. If in any doubt do not use the unit and contact an electrician/service    

 

agent.

  

WArninG! Compressor must only be serviced by an authorised agent. DO nOt tamper with, or attempt to adjust,  pressure  

 

 

switch or safety valve.

Before moving, or maintaining the compressor

 

ensure it is unplugged from the mains supply and that the air tank pressure has been vented. 

only use recommended attachments and parts. to use non-recommended items may be dangerous and will invalidate your warranty.

read the instructions regarding any accessory used with the compressor. ensure the safe working pressure of any air appliance used    

 

exceeds the compressor’s output pressure. If using a spray gun, check the area selected for spraying is provided with air change system/  

 

ventilation.

ensure the air supply valve is turned off before disconnecting the air supply hose.

to move the compressor use the handle only.  lift the compressor so that the front leg gives enough clearance for manoeuvring but  

 

 

maintain unit’s centre of gravity in front of the wheels. do not attempt to lift or move the compressor by any means other than by handle. 

use the compressor in a well ventilated area and ensure it is placed on a firm surface.

Keep tools and other items away from the compressor when it is in use and keep area clean and clear of unnecessary items.

ensure the air hose is not tangled, twisted or pinched.

Keep children and unauthorised persons away from the working area.

do not dis-assemble compressor for any reason. the unit must be checked by qualified personnel only.

do not use the compressor outdoors, or in damp, or wet, locations and do not operate within the vicinity of flammable liquids, gases or  

 

solids.

do not touch compressor cylinder, cylinder head or pipe from head to tank as these may be hot and will remain so for some time after   

 

shutdown.

do not attempt to move the compressor by pulling the air tool hose. only move the compressor by its handle.

do not use this product to perform a task for which it has not been designed.

1.1. 

eleCtriCAl SAFetY

  

WArninG!

 It is the responsibility of the owner and the operator to read, understand and comply with the following:

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other 

connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. A 

residual current circuit Breaker (rccB) should be incorporated in the main distribution board. We also recommend that a residual current 

device (rcd) is used. It is particularly important to use an rcd with portable products that are plugged into a supply which is not protected 

by an rccB. If in any doubt consult a qualified electrician. You may obtain a residual current device by contacting your sealey dealer. 

You must

 also read and understand the following instructions concerning electrical safety.

1.1.1.  the 

electricity at Work Act 1989 

requires all portable electrical appliances, if used on business premises, to be tested by a qualified  

 

electrician, using a Portable Appliance tester (PAt), at least once a year.

1.1.2.  the 

Health & Safety at Work Act 1974 

makes owners of electrical appliances responsible for the safe condition of those appliances  

 

and the safety of the appliance operators. 

if in any doubt about electrical safety, contact a qualified electrician.

1.1.3.  ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. see 1.1.1. and 1.1.2.    

 

and use a Portable Appliance tester.

1.1.4.  ensure that cables are always protected against short circuit and overload.

1.1.5.  regularly inspect power supply cables and plugs for wear or damage and check all

 

connections to ensure that none is loose.

1.1.6. 

important:

 ensure that the voltage marked on the appliance matches the power supply 

 

to be used and that the plug is fitted with the correct fuse - see fuse rating at right.

1.1.7. 

DO nOt

 pull or carry the appliance by the power cable.

1.1.8. 

DO nOt 

pull the plug from the socket by the cable.

1.1.9. 

DO nOt

 use worn or damaged cables, plugs or connectors. Immediately have any faulty 

 

item repaired or replaced by a qualified electrician. When an AstA/Bs approved uK 

 

3 pin plug is damaged, cut the cable just above the plug and 

dispose of the plug safely. 

 

fit a new plug according to the following instructions (uK only).

 

a)  Connect the Green/YellOW earth wire to the earth terminal ‘e’.

 

b)  Connect the BrOWn live wire to the live terminal ‘l’.

 

c)  Connect the BlUe neutral wire to the neutral terminal ‘n’.

 

d)  After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer  

 

 

insulation extends beyond the cable restraint and that the restraint is tight.

 

double insulated products, which are always marked with this symbol      , are fitted with live (brown) and neutral (blue) wires only.    

 

to rewire, connect the wires as indicated above - 

DO nOt

 connect either wire to the earth terminal.

1.1.10.  Products which require more than 13 amps are supplied without a plug. In this case you must contact a qualified electrician to ensure  

 

that a suitably rated supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket    

 

with your electrician.

1.1.11.  If an extension reel is used it should be fully unwound before connection. A reel with an rcd fitted is preferred since any appliance    

 

plugged into it will be protected. the cable core section is important and should be at least 1.5mm², but to be absolutely sure that the  

 

capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use   

 

of 2.5mm² section cable.  If extension reel is to be used outdoors, ensure it is marked for outdoor use.

FUSe rAtinG

 

13 AMP

Blue 

Neutral 

Wire

Yellow & Green 

Earth Wire 

Cable 

Restraint

Brown

Live 

Wire

Содержание SA2010/3

Страница 1: ...f appropriate safety devices A Residual Current Circuit Breaker RCCB should be incorporated in the main distribution board We also recommend that a Residual Current Device RCD is used It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected by an RCCB If in any doubt consult a qualified electrician You may obtain a Residual Current Dev...

Страница 2: ...5 Bar Max At 6 0 Bar Tank Capacity l Max Pressure psi bar Noise Level dB A SA2050 3 3 230 1 13 K12 C 1400 13 6 10 7 10 5 9 6 50 145 10 95 SA2010 3 3 230 1 13 K12 C 1400 13 6 10 7 10 5 9 6 100 145 10 95 SA2020 3 SA2015 3 3 3 230 1 230 1 13 13 K12 C K12 C 1700 1700 14 5 14 5 12 8 12 8 12 1 12 1 11 1 11 1 200 150 145 10 145 10 95 95 2 1 Specifications 2 2 Weights Dimensions fig 3 Model Weight kg Dime...

Страница 3: ...eset D fig 6 should not be operated until 3 minutes after cut out to allow the motor to cool To restart turn main switch off reset D and then turn main switch on If after restarting the compressor again automatically cuts out turn off at the main switch and contact Service Agent 4 6 SA2050 3 SA2010 3 The output pressure is regulated by the pressure reducer fig 4 3 Lift and turn the knob clockwise ...

Страница 4: ...damage Belt slipping Filter clogged Head gasket or valve fault Pressure switch fault Motor failure Overload cut out operated motor overheating Non return valve seal defective Contact Authorised Service Agent Adjust belt See para 5 6 b Replace filter element Contact Authorised Service Agent Contact Authorised Service Agent Contact Authorised Service Agent Press the button D to restart fig 6 Empty t...

Отзывы: