Connecting Cables between Indoor Unit and Outdoor Unit
3) Connecting the cable to Outdoor Unit
1. Remove the Cover control from the unit by
loosening a screw.
Connect the wires to the terminals on the control
board individually as following.
2. Secure the cable onto the control board with the
holder (clamper).
3. Refix the cover control to the original position with
the screw.
4. Use a recongnized circuit breaker between the
power source and the unit. A disconnection device
to adequately disconnect all supply lines must be
fitted.
After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have an individual power circuit specialized for the air conditioner. As for
the method of wiring, be guided by the circuit diagram posted on the inside of control
cover.
2) The screw which fasten the wiring in the casing of electrical fittings are liable to come
loose from vibrations to which the unit is subjected during the course of
transportation. Check them and make sure that they are all tightly fastened. (If they are
loose, it could cause burn-out of the wires.)
3) Specification of power source.
4) Confirm that electrical capacity is sufficient.
5) See to it that the starting voltage is maintained at more than 90 percent of the rated
voltage marked on the name plate.
6) Confirm the cable thickness which is specified as the power source specification.
(Particularly note the relation between cable length and thickness.
7) Always install an earth leakage circuit breaker in a wet or moist area.
8) The following would be caused by voltage drop.
•
Vibration of a magnetic switch, which will damage the contact point, fuse breaking,
disturbance of the normal function of the overload protection device.
9) The means for disconnection from a power supply shall be incorporated in the fixed
wiring and have an air gap contact separation of at least 3mm in each active(phase)
conductors.
CAUTION
•
Capacity of circuit breaker.
18k
24k
28k
30
30
30
Circuit
Breaker
(A)
Grade
Outdoor unit
Terminal block
Connecting
cable
Cover control Holder for
connecting
cable
Over 5mm
Holder for
power supply
cord
Power supply
cord
22 Convertible Air Conditioner