R
R
R
Drain Hose
BOTTOM
Drain Hose
Hose Hanger
Piping
Hose
Bracket
1
3
4
5
2
Hose Hanger
Hose
Hanger
3. Installation on the ceiling
1) Connecting the pipes to the indoor unit
The pipe can be connected to right side, bottom or
back of the unit.
1. For the Right Side Piping
•
After bending an end of the connecting tube, align
the center of the pipings and sufficiently tighten the
flare nut with fingers.
•
Finally, tighten the flare nut with torque wrench until
the wrench clicks.
•
Connect the Drain Hose insulated to the drain
outlet. Drain hose should be go through under the
Hose Bracket as shown in figure .
•
Hang the drain hose on the hose hanger and fix it
to the hole of the hose bracket with a screw.
2. For the Bottom Side Piping
•
Remove the knock-out on the bottomside of Inlet
Grille
•
Align the center of the pipings and sufficiently
tighten the flare nut with fingers.
•
Finally, tighten the flare nut with torque wrench until
the wrench clicks.
•
Connect the Drain Hose insulated to the drain
outlet.
•
Hang the drain hose on the hose hanger and fix it
to the hole of cabinet bottom with a screw.
2) Connecting the Drain Hose
•
The drain hose can be connected to not only the
right side but also left side of the unit.
•
If the drain hose is connected to the left side, it
should go through the cabinet bottom.
•
Hang the drain hose on the hose hanger and fix it
to the hole of cabinet bottom with a screw.
Installation Manual
17
Connecting Pipes to the Indoor Unit