Service Manual
15
Disassembly
9. Capacitor
1. Remove the control box. (Refer to section 3)
2. Open the top cover from the control box.
(See Figure 23)
3. Pull out the capacitor from the control box.
4. Disconnect all the leads of capacitor terminals.
5. Re-install the components by referring to the
removal procedure, above.
10. Power Cord
1. Remove the control box. (Refer to section 3)
2. Open the top cover from the control box.
(Refer to section 9)
3. Disconnect the front panel from the control box.
(See Figure 24)
4. Disconnect two leads from the capacitor and
relay.
5. Pull out the power cord.
6. Re-install the component by referring to the
above removal procedure, above.
(Use only one ground-marked hole for ground
connection.)
7. If the supply cord of this appliance is damaged, it
must be replaced by the special cord.
(The special cord means the cord which has the
same specification marked on the supply cord
attached at the unit.)
Figure 24
Figure 23
Содержание HBLG2504E
Страница 37: ...Service Manual 37 Memo ...
Страница 38: ...38 Room Air Conditioner Memo ...
Страница 39: ...P No 3828A20306J Printed in Korea ...