![LG GR-562 Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/lg/gr-562/gr-562_service-manual_1902595027.webp)
- 27 -
7-2-7 TEMPERATURE COMPENSATION & OVERCOOLING/UNDERCOOLING COMPENSATION CIRCUIT
1. Refrigerator Temperature Compensation
➧
Table of Temperature Compensation by adjusting the resistance (Difference with the current temperature)
E.g.) If the refrigerator compensation resistance (RCR1) is changed from 10K (the current resistance) to 18K
(the adjustment resistance), the temperature of the refrigerator rises +1.0 °C.
Refrigerator
Resistance
Temperature Remark
(RCR1)
Compensation
180 K
Ω
+2.5 °C
Compensation by
56 K
Ω
+2.0 °C
raising the
33 K
Ω
+1.5 °C
temperature
18 K
Ω
+1.0 °C
12 K
Ω
+0.5 °C
10 K
Ω
0 °C
Standard Temperature
8.2 K
Ω
-0.5 °C
Compensation by
5.6 K
Ω
-1.0 °C
lowering the
3.3 K
Ω
-1.5 °C
temperature
2 K
Ω
-2.0 °C
470
Ω
-2.5 °C
Содержание GR-562
Страница 32: ...7 5 MAIN PWB ASS Y AND PARTS LIST 7 5 1 MAIN PWB ASS Y 32 u u GR R562 R602 ...
Страница 33: ...7 5 2 MAIN PWB ASS Y 33 u u GR S562 S602 ...
Страница 34: ...7 5 3 REPLACEMENT PARTS LIST u u GR R562 R602 34 ...
Страница 35: ...7 5 4 REPLACEMENT PARTS LIST u u GR S562 S602 35 ...
Страница 36: ...7 5 5 PWB ASS Y DISPLAY AND PARTS LIST u u GR R562 R602 36 ...
Страница 37: ...7 5 6 PWB ASS Y DISPLAY AND PARTS LIST u u GR S562 S602 37 ...
Страница 38: ...7 6 1 PWB DIAGRAM u u GR R562 R602 38 ...
Страница 39: ... 39 ...
Страница 40: ...7 6 2 PWB DIAGRAM u u GR S562 S602 40 ...
Страница 41: ... 41 ...
Страница 46: ...P No 3828JD8858X JUN 2005 Printed in Korea ...