7-1-5 ERROR DIAGNOSTIC MODE
1. The error diagnostic mode allows the SVC when a fault that may affect the performance of the product occurs while
operating the product.
2. Even if the function control button is pushed when an error occurs, the function will not be performed.
3. When the error is cleared while the error code is displayed due to a fault, the appliance returns to the normal condition
(Reset).
4. The error code is displayed by the refrigerator temp indication LED on the display of the refrigerator while the remaining
LEDs are off.
- 22 -
GR-R562/R602
GR-S562/S602
R1
R2
R3
R4
NO
Error
Error Code Display
Cause
State of Operation with Error
R1 R2 R3 R4
Comp / Cooling fan Defrosting heater
: ON
: OFF
1.
2.
3.
Faulty refrigerator(R)
sensor (on the control
box of the refrigerator)
Faulty defrosting sensor
Defrosting failure
Cut or short-circuited wire of
refrigerator sensor
Cut or short-circuited wire of
defrosting sensor
Cut or disconnected wire of
defrosting heater or temperature
fuse(indicated at least 2 hours
later after the error occurs)
15 min ON/
15 min OFF
No defrosting
Содержание GR-562
Страница 32: ...7 5 MAIN PWB ASS Y AND PARTS LIST 7 5 1 MAIN PWB ASS Y 32 u u GR R562 R602 ...
Страница 33: ...7 5 2 MAIN PWB ASS Y 33 u u GR S562 S602 ...
Страница 34: ...7 5 3 REPLACEMENT PARTS LIST u u GR R562 R602 34 ...
Страница 35: ...7 5 4 REPLACEMENT PARTS LIST u u GR S562 S602 35 ...
Страница 36: ...7 5 5 PWB ASS Y DISPLAY AND PARTS LIST u u GR R562 R602 36 ...
Страница 37: ...7 5 6 PWB ASS Y DISPLAY AND PARTS LIST u u GR S562 S602 37 ...
Страница 38: ...7 6 1 PWB DIAGRAM u u GR R562 R602 38 ...
Страница 39: ... 39 ...
Страница 40: ...7 6 2 PWB DIAGRAM u u GR S562 S602 40 ...
Страница 41: ... 41 ...
Страница 46: ...P No 3828JD8858X JUN 2005 Printed in Korea ...