57
PROGRAMMING MODE - TEST MODE
PROGRAMMING MODE -
TEST MODE
Diagnostic tests: (display)
This program has been added for testing the washer and detecting errors.
1.
According to pressing START button, test move to the next step.
Entering the test mode
Data Name
Button
Display
Description
Entering
the test mode
1. Entering programming mode
Insert service card (card type), turn on/off toggle switch (Coin type).
2. Whites
Press the Whites button. Then
appears in the display.
3. START
Enter the diagnostic test mode.
Number of times the
START button is pressed
Check Point
Display
None
1time
Turns on all lamps and locks the door
Displays 1U:XX, 1g:XX and 12:X0 alternately (Version)
2 times
Tumble Clockwise.
rpm (40~50)
3 times
Low Speed Spin
rpm (600)
4 times
High Speed Spin
rpm (1000~1150)
5 times
Inlet valve for main water turns on.
Water level frequency (261~)
6 times
Inlet valve for hot wash turns on.
Water level frequency (261~)
7 times
Inlet valve for softener turns on.
Water level frequency (261~)
8 times
Inlet valve for bleach turns on.
Water level frequency (261~)
9 times
Tumble counter clockwise.
rpm (40~50)
10 times
Drain Pump turns on.
Water level frequency (261~)
11 times
Turn on Circulation Pump.
Displayed 0XX
12 times
Turns on all lamps.
Displays 1U:XX, 1g:XX and 12:X0 alternately
13 times
Button Checks.
14 times
High Speed Spin
rpm(1000)
15 times
PDA Signal Check
this function is not applied in this machine
16 times
Content of
NOTE
• Make sure the drum is empty when a diagnostic test is performed. Do not use .
Содержание GCW1069CS