TROUBLE SHOOTING
-11-
Fault phenomenon
Possible cause for faults
Inspection scope
Removal
Notes:
No input
voltage
existing
Poor contact between the plug
and the socket
Inspect whether the plug and the
socket are loose
Repair or replace the socket Call an electrician
for repair
White indicator
lamp not
operating
Poor contact with the white
indicator lamp
Inspect whether the connector
assembly is loose
Insert the connector assembly
tightly
Input voltage
existing
White indicator lamp damaged
Remove the white indicator lamp
Replace
Poor contact between the pink
indicator lamp and the plug
foot
Inspect whether the connector
assembly is loose
Insert the connector assembly
tightly
opening
pink indicator lamp damaged
Remove the pink indicator lamp
Replace
Call professional
for repair
No put the temperature
controller to operating state
position
Inspect the temperature controller
Put to the operating state position
as per consideration for use
Pink indicator
lamp not
operating
Poor contact with the
temperature controller
Inspect whether the connector
assembly is damaged
Insert the connector assembly
tightly
Compressor set
not opening
Temperature controller
damaged
Inspect whether open circuit
exists in two connector
assemblies
Replace the temperature controller
Too mush frosting on
evaporator
Inspect whether thickness is more
than 2mm
Remove the frost timely
Over-high frequency of
opening the door
Reduce the frequency of opening
the door as much as possible
Too mush articles in the case
Inspect whether it is possible to
impact the circulation of cool air.
Take some food out
Over-temperat
ure in the case
Refrigerating fluid leaking
Repair in a maintenance point
machine set
operating
continuously
Over-high ambient
temperature and too low
temperature of the temperature
controller
Inspect whether the knob is put
on Positions “2-4” or forced
cooling
Adjust the knob to Positions
“2-4”
Temperature in
the case
reached
Temperature controller fault
Replace the temperature controller
Case no keep flat
Inspect whether four castor
wheels touch ground
Cushion timely
Retaining screws of the compressor loosening
Inspect whether the screws are
screwed down.
Screw the screws down
Call professional
for repair
Pipelines contacting
Separate the pipeline
Starting relay and thermal protection
connector assembly loosening
Inspect whether the connector
assembly is damaged
Insert the connector assembly
tightly
Compressor damaged
Repair or replace the compressor
Call professional
for repair
Excessive noise,
red and green
indicator lamps
operating, and
compressor not
operating
Voltage less than 187V
Inspect supply voltage
Connect a voltage stabilizer over
1000V
If the supply cords are damaged, in order to avoid danger, replacement of the supply cords must be carried out by the manufacturer or its maintenance
department
Note: the following phenomenon is not the fault phenomenon
1. Slight gurgle exists in the temperature-changeable freezing refrigerator occasionally;
2 The compressor and the condenser emit heat, even scald hands;