CHAPTER 6 COMMUNICATION FUNCTION
6-45
•
Master module ‘high speed link 1’ setting completion screen
Point
Communication between LGIS Pnet I/F master and other manufacturer’s slave
1) The basic communication method is the same as the communication example
between LGIS and LGIS.
2) Select the station of slave module as the external switch of other manufacturer’s
slave module.
3) When preparing GMWIN program, designate the I/O size of other manufacturer’s
module when setting high speed link parameter.
4) When opening the communication in SyCon, seek GSD file of other manufacturer’s
module and designate it as slave, and match the station number designated by
external switch of slave module with slave station number when
creating with
SyCon.
5) The size of I/O score
created
in SyCon should be matched with GMWIN program
high speed link parameter setting and size of GMWIN program.
6) When using other manufacturer’s remote module, it is required to carry out by the
same mode as the communication example between LGIS and LGIS, apply GSD
file of the module used when created with SyCon, and designate the same I/O
contact size of the used module for SyCon and GMWIN program.