CHAPTER 6 COMMUNICATION FUNCTION
6-42
Point
1) The I/O contact size of sending area and receiving area should be set as the
same as that of KGLWIN program and SyCon.
When selecting Smart I/O module in SyCon, the sending/receiving area size of
each module shall be set automatically.(available to verify in Slave Setting
window.)
2) G4L-PUEA 1EA and GPL-TR2A(16points), GPL-D22A(16points), GPL-RY2A
(16points) are
created
in order and when setting the sending area
as %MW0, receiving area as %MW100,
* Sending area : %MW0
* Receiving area : %QW0.2.0
* Sending area size : 4 bytes(total output contact number)
* Receiving area size : 2 bytes(total input contact number)
* %MW0 data -> output to GPL-TR2A
* %MW1 data -> output to GPL-RY2A
* GPL-D22A input -> saved in %QW0.2.0
3) It doesn’t matter which one is set in advance between GMWIN program and
SyCon.
2) High speed link parameter setting in GM4(Station 0)
•
Master module GMWIN program