28
YES
Is the resistance of the
Thermistor
out of range
44 ~
53 K
Ω
at 25°C
? (Page 17)
Replace the
Main PCB
.
Is the
Connector
connected correctly to
the
Main PCB
and the
Thermistor
and the
Heater
?
Or is the
Harness
alright ?
Reconnect or repair the
Connector
.
Or replace the
Harness
.
Replace the
Thermistor
.
YES
Replace the
Heater
.
YES
NO
Is the resistance of the
Heater
out of range
24.5 ~
28.5
Ω
(for Washing) or
42.5 ~ 49.5
Ω
(for Steam) ?
(Page 19)
[Note] Thermistor Spec
NO
NO
Thermistor (Heating) Error (tE)
S
P
E
C
Temp
30 °C
40 °C
60 °C
70 °C
95 °C
105 °C
Resistance (k
Ω
)
MIN
36.35
39.45
42.72
24.20
26.05
27.97
11.43
12.12
12.82
8.088
8.514
8.940
3.544
3.791
4.045
2.617
2.816
3.023
STD
MAX
Heater for Washing
Heater for Steam
Содержание F14030RD
Страница 2: ...51 P No MFL30574776 ...
Страница 15: ...14 6 WIRING DIAGRAM PCB LAYOUT PROGRAM CHART ...
Страница 17: ...16 PCB Layout Power Common Power Cord Noise Filter DRY Wash DRY Resistance 24 5 28 5 Ω Only For Dry Combo Wash ...
Страница 18: ...17 Program Chart ...
Страница 51: ...50 10 4 THE EXPLODED VIEW OF DRYER M130 M120 M230 M140 M215 M210 M216 M100 M240 M101 M220 M111 M110 ...