NOTE: This test has two parts. The best test of the door switch system is done in the diagnostic mode. This
FUNCTIONAL TEST will test the door switch, wiring harness and PCB operation. If the results of this test are
normal, the door switch system and PCB response are normal. The problem is somewhere else.
FUNCTIONAL TEST (Control)
1. Enter the diagnostic mode. (See DIAGNOSTIC TEST MODE.)
2. With the door closed, press the START/PAUSE button once. The dryer will start tumbling without heat.
3. Open the door. The drum will stop tumbling. The “dE” error code should be displayed, the chime should sound seven times (if turned on), and
the drum light (if equipped) should come on. If the “dE” error code is not displayed or the light does not come on, proceed with the
MECHANICAL TEST below. If the error displays and light comes on, the door switch is working properly.
Test 5
kGzG{
isY
X
Z
Y
~o[
X
Z
Y
NO
NO
NO
YES
YES
YES
WH4
Disconnect the WH1 and BL3 connector
from the main PCB.
Measure the resistance between the
NA6- (GN) pin and a chassis
ground screw.
Is the resistance <1 ?
Disconnect the BL2 and WH4 connector
from the main PCB.
Measure the resistance between
BL2- (WH) and WH4- (YL).
Is the resistance <1 with the
door closed and with the door
open?
*Skip this step if the dryer does not have
a drum light.
Disconnect the WH4 and the black tab
relay connectors from the main PCB.
Measure the resistance between
WH4- (YL) and WH4- (BK).
Is the resistance <1 with the door
opened and
with the door closed?
Refer to the individual door switch and light
bulb/socket component tests.
•
Replace the main
PCB.
•
Check all wiring
harness
connections wire
and ground
screws.
•
Replace the light
bulb.
•
Replace the light
socket.
[
[
42
Содержание DLE3600 Series
Страница 13: ...13 13 13 3 3 Connect Inlet Hose 21 8 150 800 800 ...
Страница 18: ...18 18 15 ...
Страница 21: ...21 21 21 7 WIRING DIAGRAM 18 ELECTRIC DRYER GAS DRYER ...
Страница 22: ...22 22 Main PCB Picture Electric Gas 19 ...
Страница 24: ...24 24 21 ...
Страница 27: ...27 27 27 Electric Dryer Table 1 Resistance for Thermistor Temperature 25 ...
Страница 37: ...37 36 10 DIAGNOSTIC TEST 35 T ...
Страница 61: ...61 60 13 EXPLODED VIEW 13 1 Control Panel and Plate Assembly A120 A140 A110 58 A210 A211 A213 ...
Страница 66: ...66 65 MAY 2020 PRINTED IN KOREA P No MFL69290439 ...