42
43
41
Test 3
tG{
Before measuring resistance, be sure to turn the power off and discharge voltage.
(When discharging, contact the metal plug of power cord with ground wire.)
Drum dose not rotate; no blower function, no heater function.
Turn the dryer’s power off, then measure resistance.
Is resistance below 3
�
between connector
BL2- (White wire) and WH4-
(Brown wire)?
Measure while door is closed.
•
Replace control.
(Relay check)
•
Check controller
connector.
•
Check if door frame
presses door switch
knob.
•
Check door switch.
•
Check harness
connection.
•
Replace control.
(Relay check)
•
Check controller
connector.
•
Replace outlet
•
Thermostat.
(Refer to
‘component’)
•
Check idler assembly.
•
Drum belt cuts off
•
Drum belt takes off
from motor pulley.
•
Replace idler
switch.
Is resistance below 3
�
between connector
BL2- (White wire) and WH4-
(Yellow wire)?
Measure while door is closed.
Is resistance below 3
�
between connector
WH4- (Yellow wire) and WH4-
(Brown wire)?
Is resistance below 1
�
between terminals
of outlet thermostat attached to blower housing?
Does idle switch attached to motor bracket
operate level by drum belt?
(Not operating lever is normal.)
Is resistance below 1
�
between idler switch
terminals?
•
Check motor. (Refer to ‘motor diagram & check’)
• Check if control connector is contacted.
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
Caution
Trouble Symptom
Measurement Condition
isY
~o[
40
42
43
NOTE:
This test has two parts. The best test of the moisture sensing system is done in the diagnostic mode. This
FUNCTIONAL TEST will test the sensor bars, wiring harness and PCB operation. If the results of this test are normal,
the sensor system and PCB response are normal. The problem is somewhere else.
FUNCTIONAL TEST (Control)
1. Enter the diagnostic mode. (See DIAGNOSTIC TEST MODE.)
2. With the door closed, press the START/PAUSE button once. The dryer will start tumbling without heat.
3. Open the door. The drum will stop tumbling and the “dE” error code will be displayed and the chime will sound several times (if turned on).
4. With one hand, reach into the drum and place your fingers across the moisture sensor bars.
(CAUTION: The dryer drum will turn in this test. Your hand will be close to the rotating drum vanes. Keep your hand close to the filter housing to
avoid being hit by the moving vanes.)
5. Use your other hand to press the door switch. The dryer drum will start rotating automatically.
6. Observe the numerical display. Depending on conditions, the number displayed should be between 30 and 255. The numbers should start
decreasing as the control senses the moisture in your skin.
7. After you have observed the number decreasing, remove your fingers from the sensor bars. The numbers will continue to decrease for a few
seconds (minimum 30) and the begin to increase (maximum 255).
8. If this test fails, proceed with the MECHANICAL TEST below.
Test 4
tGz
YES
YES
YES
YES
NO
NO
Disconnect the NA6 connector from
the main PCB. Measure the resistance
between the NA6-
chassis ground screw.
Is the resistance <1 ?
Put a jumper between NA6- (OR)
and NA6- (BL) to create a circuit
connection for the continuity test in
the next step.
Measure the resistance between
the two moisture
sensor bars on the in the lint filter
housing inside
the drum. Is the resistance <1 ?
Check all connections and wires
between the NA6
terminal at the main PCB and the
sensor bars.
Check the resistance is 0
•
Measure the resistance of all wires.
Resistance should be <1 ?
•
Check all sensor harness connectorsfor corrosion,
loose/bent pins, broken wires, etc.
•
Check all harness wires between the main PCB and the
sensor for cuts, or broken wires.
•
Check all wiring
harness connections
wire and Ground
screws.
•
Replace the main
PCB.
(GN) pin and a
41
Содержание DLE3600 Series
Страница 13: ...13 13 13 3 3 Connect Inlet Hose 21 8 150 800 800 ...
Страница 18: ...18 18 15 ...
Страница 21: ...21 21 21 7 WIRING DIAGRAM 18 ELECTRIC DRYER GAS DRYER ...
Страница 22: ...22 22 Main PCB Picture Electric Gas 19 ...
Страница 24: ...24 24 21 ...
Страница 27: ...27 27 27 Electric Dryer Table 1 Resistance for Thermistor Temperature 25 ...
Страница 37: ...37 36 10 DIAGNOSTIC TEST 35 T ...
Страница 61: ...61 60 13 EXPLODED VIEW 13 1 Control Panel and Plate Assembly A120 A140 A110 58 A210 A211 A213 ...
Страница 66: ...66 65 MAY 2020 PRINTED IN KOREA P No MFL69290439 ...