42
43
41
Test 3
tG{
Before measuring resistance, be sure to turn the power off and discharge voltage.
(When discharging, contact the metal plug of power cord with ground wire.)
Drum dose not rotate; no blower function, no heater function.
Turn the dryer’s power off, then measure resistance.
Is resistance below 3
�
between connector
BL2- (White wire) and WH4-
(Brown wire)?
Measure while door is closed.
•
Replace control.
(Relay check)
•
Check controller
connector.
•
Check if door frame
presses door switch
knob.
•
Check door switch.
•
Check harness
connection.
•
Replace control.
(Relay check)
•
Check controller
connector.
•
Replace outlet
•
Thermostat.
(Refer to
‘component’)
•
Check idler assembly.
•
Drum belt cuts off
•
Drum belt takes off
from motor pulley.
•
Replace idler
switch.
Is resistance below 3
�
between connector
BL2- (White wire) and WH4-
(Yellow wire)?
Measure while door is closed.
Is resistance below 3
�
between connector
WH4- (Yellow wire) and WH4-
(Brown wire)?
Is resistance below 1
�
between terminals
of outlet thermostat attached to blower housing?
Does idle switch attached to motor bracket
operate level by drum belt?
(Not operating lever is normal.)
Is resistance below 1
�
between idler switch
terminals?
•
Check motor. (Refer to ‘motor diagram & check’)
• Check if control connector is contacted.
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
Caution
Trouble Symptom
Measurement Condition
isY
~o[
40
Содержание DLE3600 Series
Страница 13: ...13 13 13 3 3 Connect Inlet Hose 21 8 150 800 800 ...
Страница 18: ...18 18 15 ...
Страница 21: ...21 21 21 7 WIRING DIAGRAM 18 ELECTRIC DRYER GAS DRYER ...
Страница 22: ...22 22 Main PCB Picture Electric Gas 19 ...
Страница 24: ...24 24 21 ...
Страница 27: ...27 27 27 Electric Dryer Table 1 Resistance for Thermistor Temperature 25 ...
Страница 37: ...37 36 10 DIAGNOSTIC TEST 35 T ...
Страница 61: ...61 60 13 EXPLODED VIEW 13 1 Control Panel and Plate Assembly A120 A140 A110 58 A210 A211 A213 ...
Страница 66: ...66 65 MAY 2020 PRINTED IN KOREA P No MFL69290439 ...