Troubleshooting
72
Troubleshoo
ting
4
Battery Error Code
y
Each battery is indicated by # 1, # 2, each battery share a code error.
Code
Message
Description
Solution
B184 Under SOC Warning
SOC Voltage level of battery cell is
lower than the limitation
Automatically restart after
detecting fault
B185
Over SOC Warning
SOC Voltage level of battery cell is
higher than the limitation
Automatically restart after
detecting fault
B186 Over Discharge Power
Limit
Discharge Power of the battery is
lower than the limitation
Automatically restart after
detecting fault
B187 Over Charge Power
Limit
Charge Power of the battery is
higher than the limitation
Automatically restart after
detecting fault
B188 Over Discharge
Current
Current level of the battery is
lower than the limitation
Automatically restart after
detecting fault
B189 Over Charge Current
Warning
Current level of the battery is
higher than the limitation
Automatically restart after
detecting fault
B191 Temperature
Deviation Warning
Temperature differences between
the batteries are over the limitation
Automatically restart after
detecting fault
B192 Under Temperature
warning
The battery temperature is lower
than the limitation
Automatically restart after
detecting fault
B193 Cell Voltage Imbalance
Warning
Cell Voltage differences between
the battery cells are higher than
the limitation
Automatically restart after
detecting fault
B194 Cell Under Voltage
Warning
Cell Voltage level of battery cell is
lower than the limitation
Automatically restart after
detecting fault
B195
Cell Over Voltage
Warning
Cell Voltage level of battery cell is
higher than the limitation
Automatically restart after
detecting fault
B601 Battery Monitoring IC
Loss Of
Battery Monitoring IC Loss Of
Communication Fault
Automatically restart after
detecting fault
B606 Over Discharge Power
Limit
Discharge Power of the battery is
lower than the limitation
Automatically restart after
detecting fault
B607 Over Charge Power
Limit Fault
Charge Power of the battery is
higher than the limitation
Automatically restart after
detecting fault
B608 Over Discharge
Current Fault
Current level of the battery is
lower than the limitation
Automatically restart after
detecting fault
B609 Over Charge Current
Fault
Current level of the battery is
higher than the limitation
Automatically restart after
detecting fault