Settings
54
Settings
3
[Other function] Settings
Select [Other Function] on [Installler Settings] to display [Heat Pump], [Reboot], [Password
Change], [Factory Reset] and [Dump Log] options.
[heat Pump]
Select [Heat Pump] to customize the heat pump
settings. Description of each setting value is as
follows.
y
SoC, H/P DHW On(%) : A criteria of SoC to
change high desired temperature
y
SoC, H/P DHW Off(%) : A criteria of SoC to
change original desired temperature
y
Surplus Power, H/P DHW On(W) : A criteria
of surplus power to change high desired
temperature
(Surplus Power = PV Power – Load Power)
y
DHW Desired Temperature(°C) : A high desired
temperature to change in case of H/P DHW
On
[Reboot]
Select [Reboot] to reboot system.
[Password change]
Select [Password Change] on [Installer Settings]. The [Change Password] menu is displayed.
Enter the new password in the [New Password] and [Password Check] filed. And then selelct
[Change Password] to complete the password changing.
[factory Reset]
Select [Factory Reset] to set all the system settings to its original default. All the settings and
system logs will be deleted after resetting.
[dump log]
You can save the system log file into the SD memory card with this option. Front cover of the
system must be removed to insert a SD memory card.
NOTE
If you lose your password, type “passinit” at Login popup to return to the initial password
(Registration Number).