- 43 -
Yes
No
Yes
Replace the receiver
The receiver will work
properly.
No
No
Yes
Check again
Check the signal level of
RCVP & RCVN at R219, R227. Are
these levels about 1.2V?
Check the contact state of
receiver.
Check the soldering
R219 & R227
START
Re-soldering
R219, R227
Replace the Main board.
ABB is out of order.