37
Test 1
120V AC Electrical Supply
Trouble Symptom
Measurement Condition
No power was applied to controller. (LED, LCD Display off)
With Dryer Power On; connector linked to controller.
Check the outlet, is the voltage
110V ~ 125V AC?
YES
NO
• Check the fuse
or circuit breaker.
Check if the voltage measured between
Connector BK2 or WH2-
②
(Black Wire)
Linked to the Controller and WH1-
①
(White Wire) Is 110~125V?
YES
NO
1
1
2
BK2 or WH2 WH1
BK
WH
• Check if power
cord is properly
connected.
• Reconnect the
controller.
Replace controIler.
①
Check if the controller wire is
disconnected.
②
Check if terminal block and power cord
are connected (Check Plug).
- Does Power Cord N (Natural) line match
to Terminal Center N (Natural) line?
YES
NO
L (Black)
L (Led)
N (White)